Step
Action
1
Press start button (14). The compressor starts running in unloaded condition. Automatic
operation LED (7) lights up.
2
Approx. 10 seconds later (programmable), the compressor starts running loaded. The
message on display (1) changes from -Automatically unloaded- to -Automatically
loaded-.
3
Regulate the cooling water flow (using the water flow regulating valves) with the
compressor running loaded. Adjust the water flow to obtain the most suitable air
temperature at the outlet of the compressor elements. The temperature must be
between 2 and approx. 7 ˚C (3.6 and approx. 12.6 ˚F) above the relevant temperature in
the diagram.
Minimum allowable air temperature at outlet of the compressor element(s)
Reference
Name
A
Air inlet temperature in ˚C
B
Condensation temperature in ˚C
C
Effective working pressure in bar
D
Relative air humidity in %
Example
Ambient temperature 20 ºC (68 °F).
Relative humidity 100%.
Instruction book
62
APF219617