Service
EN
LTV39-2 R56-HAD
12
© Atlas Copco Industrial Technique AB - 9839 2906 01
Bolt size
Torque range
Nm
Ordering No.
Torque rate
Nm/rev.
Degrees at
rated
capacity
Service kit*
M14
90
4080 0791 91
60
540
4080 0791 80
M16
200
4080 0866 90
200
360
4080 0865 80
M20
400
4080 0868 90
400
360
4080 0867 80
M30
800
4080 0876 92
800
360
4080 0867 80
* Including 2x bolts, 2x nuts, 2x washers
In-line torque transducers – Torque models
Model
Drive Hex inch
Drive Square
inch
Rated capacity
Nm
ft lb
Ordering No
IRTT 5-I06
¼
5
4
8092 1129 05
IRTT 20-I06
¼
20
15
8092 1129 10
IRTT 20-06
¼
20
15
8092 1129 15
IRTT 25-10
3/8
25
18
8092 1129 20
IRTT 75-10
3/8
75
55
8092 1129 25
IRTT 180-13
½
180
133
8092 1129 30
IRTT 500-20
¾
500
369
8092 1129 35
IRTT 750-25
1
750
553
8092 1129 40
IRTT 1400-25
1
1400
1033
8092 1129 45
In-line torque transducers – Torque/angle models
Model
Drive Hex inch
Drive Square
inch
Rated capacity
Nm
ft lb
Ordering No
IRTT 2A-I06
½
2
1.5
8092 1130 01
IRTT 5A-I06
¼
5
4
8092 1130 06
IRTT 20A-I06
¼
20
15
8092 1130 11
IRTT 20A-06
¼
20
15
8092 1130 16
IRTT 25A-10
3/8
25
18
8092 1130 21
IRTT 75A-10
3/8
75
55
8092 1130 26
IRTT 180A-13
½
180
133
8092 1130 31
IRTT 500A-20
¾
500
369
8092 1130 36
IRTT 750A-25
1
750
553
8092 1130 41
IRTT 1400A-25
1
1400
1033
8092 1130 46
IRTT 3000A-38
1½
3000
3000
8092 1130 51
Service instructions
Overhaul and preventive maintenance is recommended at regular intervals once per year or after maxi-
mum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed, if
used at high torque and long tightening times. If the machine is not working properly, it should immediately
be taken away for inspection.
The strainer at the air inlet and the exhaust silencer should be cleaned frequently or replaced in order to
prevent clogging, which decreases the capacity.
At the overhauls, all parts should be cleaned accurately and defective or worn parts (i.e. O-rings, vanes)
should be replaced.