Type
V
Hz
Approval
I
tot
P
(1)
I
tot
FF
(1)
Recommended
wire section (2)
Recommended
wire section (3)
Main
fuses P
(A) (4)
Main
fuses
FF (A)
(4)
GA 22
575
60
cULus /
cCSAus
35.9
39.9
AWG8
AWG6
50
60
GA 26
230
50
IEC
99.3
109.3 70 mm² / 35
mm²
95 mm² / 50
mm²
160
160
GA 26
230
60
IEC
99.9
109.9 70 mm² / 35
mm²
95 mm² / 50
mm²
160
160
GA 26
380
60
IEC
50.2
56.2
35 mm² / 16
mm²
35 mm² / 25
mm²
125
125
GA 26
400
50
IEC
57
62.7
25 mm² / 16
mm²
35 mm² / 16
mm²
80
80
GA 26
460
60
IEC
50.1
55.1
25 mm² / 16
mm²
25 mm² / 16
mm²
80
80
GA 26
200
60
cULus /
cCSAus
111.8 123.3 AWG1/0
AWG2/0
150
175
GA 26
230
60
cULus /
cCSAus
99.6
109.6 AWG1/0
AWG2/0
150
175
GA 26
460
60
cULus /
cCSAus
50
55
AWG4
AWG4
80
80
GA 26
575
60
cULus /
cCSAus
41.9
45.9
AWG6
AWG6
60
60
Remarks :
(1): current in the supply lines at maximum load and nominal voltage
(2): suggested wire section under worst case conditions (Pack)
(3): suggested wire section under worst case conditions (Full-Feature)
(4): Maximum fuse value
Fuse specifications IEC: aM
Fuse specifications UL/cUL: HRC Form II - UL: Class RK5
14.3 Motor overload relay settings
Type
V
Hz
Approval
Setting F21 (A)
Setting Q15 (A)
GA 15
230
50
IEC
36
0.7
GA 15
230
60
IEC
36.6
0.7
GA 15
380
60
IEC
25.9
0.4
GA 15
400
50
IEC
20.6
0.4
GA 15
460
60
IEC
18.3
0.4
GA 15
200
60
cULus / cCSAus
41.2
0.7
GA 15
230
60
cULus / cCSAus
36.6
0.7
GA 15
460
60
cULus / cCSAus
18.3
0.5
Instruction book
2920 7140 90
151
Summary of Contents for GA15