BV2 starts closing the bypass line and opening the oil supply line from the ER heat exchanger (HE) at the
lower limit of its temperature range. At the upper limit of its temperature range, the bypass line is completely
closed and all the oil flows through the ER heat exchanger.
On compressors versions with a maximum pressure lower than 13 bar, BV2 starts opening at 40 °C and is
completely open at 55 °C .
On compressors with a maximal pressure of 13 bar , BV2 starts opening at 60 °C and is completely open at 75
°C.
The housing of BV2 is provided with a special handle (V1), allowing to control the working of the energy
recovery system.
As can be seen on the ER label, the ER unit is integrated in the oil circuit and will recover energy when the
handle is completely turned in clockwise.
When the handle is turned out anticlockwise, the heat exchanger (HE) is bypassed and no energy will be
recovered.
Reference
Designation
BV2
Thermostatic bypass valve of ER unit
HE
Oil/water heat exchanger (ER unit)
E
Compressor element
Co
Oil cooler (compressor)
1
Water inlet
Summary of Contents for GA 55+
Page 1: ...GA 55 GA 75 GA 90 Instruction book Atlas Copco Oil injected rotary screw compressors ...
Page 2: ......
Page 4: ......
Page 9: ......
Page 96: ...96 Instruction book 9096331300 6 Installation 6 1 Dimension drawings Centre of gravity ...
Page 98: ...98 Instruction book 9096331300 6 2 Installation proposal Compressor room example ...
Page 109: ...109 Instruction book 9096331300 ...
Page 123: ...123 Instruction book 9096331300 Procedure Oil system components Oil drain plugs ...
Page 145: ...145 Instruction book 9096331300 Notes ...
Page 146: ...146 Instruction book 9096331300 Notes ...
Page 147: ...147 Instruction book 9096331300 Notes ...
Page 148: ......
Page 149: ......