141
Instruction book
9096 3313 00
(1): from approx. April 30, 2009 onwards
11.8 Technical data Elektronikon® controller
General
Units
7. 5 bar
8 bar
10 b ar
13 bar
Refrigerant type, Full-
Feature units
R4 04 a
R40 4a
R 404 a
R40 4a
Refrigerant type, Full-
Feature units (1)
R410A
R4 10 A
R 41 0A
R4 10 A
Refrigerant quantity,
Full-Feature units
kg
2.55
1.8
1.8
1.4
Refrigerant quantity,
Full-Feature units (1)
kg
1.5
1.2
1.2
0.97
Cooling water
consumption (at water
inlet temperature below
35 °C and temperature
rise of 15 °C), water-
cooled units
l/min
103
103
103
103
Cooling water
consumption (at
water inlet
temperature between
35 and 40 °C and
temperature rise of
10 °C), water-cooled
units
l/min
154
154
154
154
Oil capacity, air-cooled
units
I
30
30
30
30
Oil capacity, water-
cooled units
l
25
25
25
25
Sound pressure level
(according to ISO
2151 (2004))
dB(A)
73
73
73
73
Parameter
Value
Supply voltage
24 V AC /16 VA 50/60Hz
(+40%/-30%) 24 V DC/0.7
A
Type of protection
IP54 (front)
IP54 (back)
Ambient and temperature conditions
IEC60068-2
Temperature range
•
Operating
•
Storage
•
-10
o
C ….. +60
o
C
•
-30
o
C ……+70
o
C
Permissible humidity
Relative humidity 90%
No condensation
Noise emission
IEC61000-6-3
Noise immunity
IEC61000-6-2
Mounting
Cabinet door
Summary of Contents for GA 55+
Page 1: ...GA 55 GA 75 GA 90 Instruction book Atlas Copco Oil injected rotary screw compressors ...
Page 2: ......
Page 4: ......
Page 9: ......
Page 96: ...96 Instruction book 9096331300 6 Installation 6 1 Dimension drawings Centre of gravity ...
Page 98: ...98 Instruction book 9096331300 6 2 Installation proposal Compressor room example ...
Page 109: ...109 Instruction book 9096331300 ...
Page 123: ...123 Instruction book 9096331300 Procedure Oil system components Oil drain plugs ...
Page 145: ...145 Instruction book 9096331300 Notes ...
Page 146: ...146 Instruction book 9096331300 Notes ...
Page 147: ...147 Instruction book 9096331300 Notes ...
Page 148: ......
Page 149: ......