A number of protection settings are provided. The protection screens are labelled <Pr.>. The pictograph
shown with the protection screen indicates the purpose of the protection.
Possible combinations are <Pr.>, followed by a number and one of the next pictographs:
Pictograph
Designation
<Pr.> combined with the pressure pictograph shows the pressure protections.
<Pr.> combined with the element outlet temperature pictograph shows the element
outlet temperature protections.
<Pr.> combined with the dew point temperature pictograph shows the dew point
temperature protections.
<Pr.> combined with the ambient temperature pictograph shows the ambient
temperature protections.
Following protection settings are available:
• A low warning level, shown on the display as <AL-L>.
• A high warning level, shown on the display as <AL-H>.
• A low shutdown level, shown on the display as <Sd-L>.
• A high shutdown level, shown on the display as <Sd-H>.
• A low service level shown on the display as <SE-L>.
• A high service level shown on the display as <SE-H>.
Example of protection screens
In this menu the temperature protection settings can be checked and modified.
Changing the settings
Starting from the Main screen (the example given describes the protection of the element outlet
temperatures):
Instruction book
2920 7180 30
55
Summary of Contents for GA 30+
Page 1: ...Atlas Copco Oil injected rotary screw compressors GA 30 GA 37 GA 45 Instruction book ...
Page 2: ......
Page 15: ...Motor side view GA 30 up to GA 45 Pack Instruction book 2920 7180 30 13 ...
Page 16: ...Service side view GA 30 up to GA 45 Pack Instruction book 14 2920 7180 30 ...
Page 17: ...Motor side view GA 30 up to GA 45 Full Feature Instruction book 2920 7180 30 15 ...
Page 188: ......
Page 189: ......