5.1.3
Operation
Description
The compressor oil flow is controlled by two thermostatic valves (BV1 and BV2), ensuring reliable
compressor operation and optimum energy recovery.
Bypass valve (BV1) is integrated in the oil filter housing of the compressor and controls the oil flow to the
heat exchanger (HE) and the main oil cooler (Co) of the compressor. Bypass valve (BV2) controls the oil
flow through the oil/water heat exchanger (HE) of the ER unit. Both valves consist of an insert (thermostat)
mounted in a housing.
Instruction book
2920 7109 23
85