10
Outlet cooling air grating of the air cooler and the oil cooler.
11
Outlet cooling air grating of the dryer.
12
Bypass system to bypass the dryer during service operations (available as an option, consult
Atlas Copco).
Safety
Apply all relevant safety precautions, including those mentioned in this book.
Outdoor/altitude operation
The compressors are not designed for outdoor use.
The compressors can only be used in temperatures above 0 °C (+32 °F). If frost might occur, the
appropriate measures should be taken to avoid damage to the machine and its ancillary equipment. In this
case, consult Atlas Copco.
Also if operating above 1000 m (3300 ft), consult Atlas Copco.
Moving/lifting
The compressor can be moved by a lift truck using the slots in the frame. Take care not to damage the
bodywork during lifting or transport. Before lifting, reinstall the transport securing bolts. Make sure that
the forks protrude from the other side of the frame. The compressor can also be lifted after inserting beams
in the slots. Make sure that the beams cannot slide and that they protrude from the frame equally. The
chains must be held parallel to the bodywork by chain spreaders in order not to damage the compressor.
The lifting equipment must be placed in such a way that the compressor is lifted perpendicularly. Lift
gently and avoid twisting.
In case of units equipped with the Lifting Device Option, it is not allowed to lift the
compressor if the canopy parts or lifting supports are not completely installed. When the
compressor is being lifted, it is also forbidden to come under the load or to perform
maintenance activities to it.
Acclimatization
When moving the compressor into an installation room, forming of condense can occur
on some components.
To avoid dew harming of electrical components, ensure at least 2 hours of
acclimatization before switch on the compressor.
4.3
Electrical connections
Working with machinery controlled by a frequency converter requires special safety
precautions. These safety precautions depend on the kind of network used (TN, TT, IT
system). Consult Atlas Copco.
Instruction book
78
2920 7109 23