been exceeded. Carry out the service actions of the indicated plans or replace the component and reset the
relevant timer, see section
.
Stopping
Step
Action
1
Press stop button (9). Automatic operation LED (8) goes out and the compressor stops.
2
Close the air outlet valve.
3
Press the test button on top of the electronic water drain(s) to the depressurize the piping
between air receiver and outlet valve, next open the manual drain valve (Dm). See section
.
Switch off the voltage.
To stop the compressor in the event of an emergency
, press emergency stop button (10).
Alarm LED flashes (7).
• Remedy the problem cause.
• Next, unlock the button by pulling it out.
• Next, navigate to the Stop icon on the display by means of the navigation keys (3/4) and
press the Select key.
Press Reset.
Do not use emergency stop button (10) for normal stopping!
Taking out of operation
Step
Action
1
Disconnect the compressor from the mains.
2
Unscrew the oil filler plug only one turn to permit any pressure in the system to escape.
3
Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
4
Drain the oil.
5
Drain the condensate circuit and disconnect the condensate piping from the condensate net.
Instruction book
2920 7109 23
101