Fault code
Cause
Actions
1
Overcurrent
Contact Atlas Copco
Ground fault
Contact Atlas Copco
2
Too high voltage. The voltage on the
converter is above the specifications.
Check the supply voltage
Contact Atlas Copco.
3
Too low voltage. The voltage on the
converter is below the specifications.
Power quality faults
Check the supply voltage
Contact Atlas Copco
Check for loose wiring/wiring errors
Check supply voltage during start up
Check fuses transformer (200V, 230V,
500V and 575V units only)
4
Drive overload
Contact Atlas Copco
8
Converter overheating (heat sink)
Check the ambient temperature
Check the cubicle cooling
Check airflow around drive
Check cooling fan and cooler
contamination
Contact Atlas Copco
256
Hardware fault
Contact Atlas Copco
512
Motor overload
Contact Atlas Copco
Drive overload
Contact Atlas Copco
Over-torque detection
Contact Atlas Copco
Under-torque detection
Contact Atlas Copco
1024
Over-speed
Contact Atlas Copco
Safe torque off
Check for loose wiring at inverter -
Push
emergency stop button
Check temperature switch
8192
Output phase loss
Contact Atlas Copco
Input phase loss
Check supply voltage
Check for loose wiring/wiring errors
Check supply voltage during start-up
Check fuses transformer (200V, 230V,
500V and 575V units only)
16384
Communication error
Contact Atlas Copco
TIME-OUT
Time-out communication error between
Elektronikon and Inverter
Contact Atlas Copco
Faults and remedies, dryer
For all references hereafter, consult section
Condition
Fault
Remedy
Pressure dew point too high
Air inlet temperature too high
Check and correct; if necessary, clean the
aftercooler of the compressor
Ambient temperature too high Check and correct; if necessary, draw
cooling air via a duct from a cooler place or
relocate the compressor