These declared values were obtained by laboratory type testing in accordance with the stated directive or
standards and are suitable for comparison with the declared values of other machines tested in accordance
with the same directive or standards. These declared values are not suitable for use in risk assessments and
values measured in individual work places may be higher. The actual exposure values and risk of harm
experienced by an individual user are unique and depend upon the way the user works, in what material the
machine is used, as well as upon the exposure time and the physical condition of the user, and the condition
of the machine.
We, Construction Tools EOOD, cannot be held liable for the consequences of using the declared values, instead
of values reflecting the actual exposure, in an individual risk assessment in a work place situation over which
we have no control.
This machine may cause hand-arm vibration syndrome if its use is not adequately managed. An EU guide to
managing hand-arm vibration can be found at http://www.humanvibration.com/humanvibration/EU/VIBGUIDE.html
We recommend a programme of health surveillance to detect early symptoms which may relate to vibration
exposure, so that management procedures can be modified to help prevent future impairment.
Noise and vibration data
Vibration
Noise
Declared values
Declared values
Three axes values
Sound power
Sound
pressure
EN ISO 20643
2000/14/EC
EN ISO
11201
permitted working
hours/day
m/s
2
value
Lw
measured
dB(A) rel 1pW
Lw
guaranteed
dB(A) rel 1pW
Lp
at
operator's
ear
Type
5.2
6.2
97
100
84
BG 240
Permitted working hours per day are calculated on action value of 5 m/s
2
as per 2002/44/EC.
Uncertainties, sound value
Uncertainties, sound value
K
pA
dB(A)
K
wA
dB(A)
Type
2.5
2.5
BG 240
Uncertainty factor for concrete.
© 2051 Construction Tools EOOD | No. 9800 1224 01b | 2051-05-18
Original instructions
26