GLASS RECEIVER CHANNEL MUST BE INSTALLED ONTO THE WATERPROOFING BEFORE THE WALLS ARE 

TILED 

INSTRUCTIONS FOR FX-NTRB 

CONFIGURATION 

1.

 

Position the glass receiver channel over the base 
glazing channel. Use 
a straight edge and 
mark the wall to 
indicate where the 
wall channel is 
plumb.  

 
 

2.

 

Apply a silicon seal 
to full length of 
channel. Silicon 
used must be 
compatible with 
anodised 
aluminium as well 
as the 
waterproofing 
being used.

 

 

3.

 

Ensure the glass receiver channel is located firmly 
over the base glazing channel. The machine recess 
in the wall glazing 
channel must firmly 
locate over the base 
glazing channel. 
Locate the framing 
timber. Use the 
4mm drill bit to drill 
holes through the 
glass receiver 
channel. Fix four 
screws through the 
channel in the wall framing (use wall plugs if 
required).  

 

4.

 

Apply a continuous bead of silicon to the full 
length of the 
channel and 
waterproofing, 
indicated by the 
dark line (inside 
channel).  

 

 

5.

 

Slide the sill infill into position and apply 6mm 
plastic packers 
into the base 
glazing channel in 
locations as 
shown.  

 

 
 
 
 

6.

 

CRITICAL SEAL 

Remove the dust and 
dirt first. Seal the 
connection between 
the glass receiver 
channel and the base 
glazing channel with 
clear silicon, prior to the installation of panel 

21 B. 

Ensure the corner junction between wall channel 
and base channel is full of silicon before final glass 

placement. It is vital that 
all junctions are sealed 
sufficiently.

 

Prior to installation of 
fixed panel and infill all 
connections of channels 
must be sealed with 
clear silicon supplied.

 

 

 
 
 

7.

 

Locate the glass panel 

21 B 

into the glazing 

channels. The top of the panels should align to the 
top of the glass receiver channel. 