INSTRUCTIONS FOR FX-TRB
CONFIGURATION
1.
Position the glass receiver channel over the base
glazing channel.
Use a straight
edge and mark the
wall to indicate
where the wall
channel is plumb.
2.
Apply a silicon seal to full length of channel.
Silicon used must be compatible with anodised
aluminium as well as the waterproofing being
used.
3.
Ensure the glass receiver channel is located
firmly over the base glazing channel. The
machine recess in the wall glazing channel must
firmly locate over the base glazing channel.
Locate the framing timber. Use the 4mm drill bit
to drill holes
through the
glass receiver
channel. Fix four
screws through
the channel in
the wall framing
(use wall plugs if
required).
4.
Apply a continuous bead of silicon to the full
length of the
channel and
waterproofing,
indicated by
the dark line
(inside
channel).
5.
PREPARATION FOR GLASS INSTALLATION
Slide the sill
infill into
position and
apply 6mm
plastic packers
into the base
glazing channel
in locations as
shown.
6.
CRITICAL SEAL
Remove the dust and dirt first. Seal the
connection between the
glass receiver channel
and the base glazing
channel with clear
silicon, prior to the
installation of panel
21
B.
Ensure the corner junction between wall
channel and base channel is full of silicon before
final glass
placement. It is vital
that all junctions are
sealed sufficiently.
Prior to installation
of fixed panel and
infill all connections
of channels must be
sealed with clear
silicon supplied.
7.
INSTALLATION OF FIXED PANEL
Locate the glass panel
21 B
into the glazing
channels. The top of
the panels should
align to the top of the
glass receiver
channel.
Add or remove plastic
packers in the base
glazing as necessary.
8.
SILL INFILL
Apply a continuous bead of silicon to each inside
face of the base channel. Ensure the ends of the
infill are
sealed and
place into
the base
channel in
the location as shown.