background image

P R E S E N T A T I O N

T h e   n o n - c o n t a c t   W C - c o n t r o l

Summary of Contents for SanTec FLUSH

Page 1: ...P R E S E N T A T I O N T h e n o n c o n t a c t W C c o n t r o l ...

Page 2: ... unit 230V 12V 50Hz Maximum hygiene due to automatical and manual activation and as well optional intermediate flush for handicapped areas Easy and quick installation on every flushing cistern type SanTec SLK or Geberit UP 300 Upgrading is possible at every time due to a battery operated electronics Manual flushing Additional mechanical release due to push button possible power blackout or empty b...

Page 3: ...SanTec FLUSH 12V UP 300 Matt chromium art no 100 136 Infrared WC control for 12 external Shine chromium art no 102 321 supply suitable for Geberit UP 300 White art no 102 338 cistern Steel art no 102 796 SanTec 230V power unit art no 231 120 SanTec FIX WC SanTec SLK art no 102 918 SanTec FIX WC UP 300 art no 101 829 T h e n o n c o n t a c t W C c o n t r o l Types and art no Automatic flushing af...

Page 4: ...h close range reflex via hand in front of the infrared window or manual by pushing the push button Automatic flushing after use minimum stay time 15 sec only at programs 2 and 3 Intermediate flushing every 10 min only at program 3 Front panel 250 x 165 mm Material front panel ABS Available surfaces matt chromium shine chromium white steel SanTec FLUSH Page 4 T h e n o n c o n t a c t W C c o n t r...

Page 5: ...ards a new programming is possible The device makes a selftest then the diagnostics LED flashes 3 times quickly From that time there are 10 sec for adjusting the flushing program Via close range reflex hold hand approx 2 cm in front of infrared window see picture it is now possible to choose between 3 different programs 1 slow flash program 1 no automatic flushing via close range reflex only manua...

Page 6: ...itionally Wall mounted box for power supply unit Location user defined WimTec GmbH Netzteil 230V 12V 50 Hz BV02071 L N 1 2 230V 20mA 12V 2VA 230V 50Hz SanTec FIX Mounting element for the installation of prop handles Art Nr 101 881 for non barrier free sanitary rooms Power supply only for type 12V neccessary 12V Supply Motor lifter Mounting frame Electronic panel Battery or power operation Conducti...

Page 7: ...lt push botton rod and backing board lead through the cable of the motor lifter resp the power supply only 12V type Install mounting frame and adjust push botton bolt 1 4 5 2 Insert bearing block with integrated motor lifter 3 SanTec FLUSH Page 7 Installation Exchange pull clamp remove the blue clamp and insert the black one Mount fixing clamp for push bolt 6 ...

Page 8: ...anTec FLUSH 12V Connect main supply 230V Connect 12V power supply to control CAUTION Don t install the transformer in the cistern Installation according IP20 e g in a wall mounted box inserted ceiling or junction box Mounting and installation must be perfor med by licensed craftsmen to ÖVE EN 8001 and VDE 0100 Install front panel and fix it with the safty screws on both sides After 60 sec the devi...

Page 9: ...ble from the motor lifter Insert battery case and plug connector 7 10 11 8 Insert batteries pay attention to polarity 9 SanTec FLUSH Page 9 Installation SanTec FLUSH 6V Lift of the cover carefully upright and unplug the battery case Install front panel and fix it with the safety screws on both sides After 60 sec the device is ready for operation 12 ...

Page 10: ...t chromium art no 232 097 6V shine chromium art no 232 103 6V white art no 232 110 6V steel for Geberit UP 300 flushing cistern art no 231 144 12V matt chromium art no 231 151 12V shine chromium art no 231 168 12V white art no 231 335 12V steel art no 231 175 6V matt chromium art no 231 182 6V shine chromium art no 231 199 6V white art no 231 342 6V steel Flush box for Power supply unit art no 101...

Page 11: ...nnection 12V 50 Hz power supply connection to motor lifter connection 12V to SanTec FLUSH power supply 230V 50 Hz External Power supply unit suitable for installation in control cabinets Accessory not included in scope of supply Art No 231 120 Place of installation according to protection class IP20 as desired Allowed cable length to electronics up to max 50 m active range controller approx at 60 ...

Page 12: ...fter active range controller approx at 60 cm pre adjusted 30 80 cm adjustable Battery case Battery type 2 pcs CRP2P lithium 6V Replace always both batteries Pay attention to polarity WimTec Elektronische Steuerungs u Meßgeräte GmbH p A 3325 Ferschnitz Freidegg 50 t 0 74 73 5000 f 500 m verkauf wimtec com www wimtec com Edition 29 05 2007 Presentation SanTec FLUSH English ...

Reviews: