![Atlantic AEYC-0639U-AT Installation Manual Download Page 58](http://html.mh-extra.com/html/atlantic/aeyc-0639u-at/aeyc-0639u-at_installation-manual_2999728058.webp)
- 58 -
■ Configuration 2: 2 heating circuits.
PC
SE
MH
R
VF
Db
VE
SP
SDpM
CCM
M
VM
CAR
CC
Bd
SA2
SA1
K2c
Key:
Bd
- Decoupling cylinder
CAR
- Check valve
CC
- Direct circuit circulation pump
CCM
- Mixed circuit circulation
Db
- Flow-meter
K2c
- 2-circuit kit
MH
- Hydraulic unit
PC
- Underfloor heating
R
- Radiator
Rdyn*
- Dynamic radiator
SA1
- Room thermostat (option/circuit 1)
SA2
- Room thermostat (option/circuit 2)
SE
- Outdoor sensor
SP
-
Thermal safety device for under-floor heating
VE
- Expansion vessel
VF
- Filter valve
VM
- Mixing valve
Heat pump
Aurea M / Installation / 1883 - EN