- 33 -
fig. 29 - Slope of the heating curve (line 720)
fig. 30 - Slope of the heating curve (line 721)
fig. 31 -
Corrective actions in case of discomfort
&
&
&
&
&
&
&
&
&
Feelings...
... in warm weather
... in cold weather
Slope (line
720
)
Shift (line
721
)
No correction
No correction
No correction
No correction
No correction
OK
OK
OK
OK
OK
OK
Cold
Cold
Cold
Cold
Cold
Hot
Hot
Hot
Hot
Hot
Hot
Cold
No correction
Corrective actions
on the weather-dependent setpoint:
40
50
60
70
-20
-15
-10
-5
5
10
-4,5
+4,5
20
0
10
30
0
30
Heating start
temperature °C
Outdoor temperature °C
Displacement
Weather-dependent
setpoint slope
0.5
90
80
70
60
50
40
30
° C
100
° C
20
-20
10
1
0.75
1.75
0.5
0.25
1.25
-10
0
2
1.5
2.75
3
2.25
2.5
Application PAC seule
Pente de la
courbe de chauffe
Radiateur classique
Radiateur dynamique
Radiateur BT
(basse température)
Plancher chauffant
Température départ chau
ffage
°C
Température extérieure °C
Outdoor temperature °C
Heat pump application only
Heating start temperature °C
Underfloor heating
Dynamic radiator
Low temperature radiator
Traditional radiator
Heating curve
slope
Aurea M / Installation / 1883 - EN