- 41 -
Line
Function
Setting range or display
Setting
increment
Basic
setting
1050
S
Room influence
1 %... 100 %
1 %
50 %
If the installation is fitted with a room thermostat:
This function enables you to choose the ambient temperature's influence on the setting.
If no value is entered, the setting is made based on the temperature control.
If the parameter is set at 100%, the setting is only based on the ambient temperature.
1060
S
Room temperature limitation
0.5... 4 °C
0.5 °C
0.5 °C
As soon as the room temperature = [Setpoint line
1010
(ex. 20 °C) + Room temperature limitation setpoint line
1060
(ex. 0.5 °C)] > 20.5 °C => The heat pump is stopped. It restarts when the room temperature falls below the setpoint
(in the example, Room temperature < 20.0 °C).
1080
S
Quick setback
Off, Up to reduced setpoint,
Up to protection setpoint
Off
1090
S
Optimum start control max
0... 360 min
10 min
180 min
1091
S
Optimum stop control max
0... 360 min
10 min
30 min
1100
S
Reduced setpoint increase start
-30... 10 °C
1 °C
--
1101
S
Reduced setpoint increase end
-30... 10 °C
1 °C
-5 °C
1130
S
Mixer valve increase
0... 50 °C
1 °C
0 °C
1134
S
Actuator running time
30... 650 s
1 s
240 s
1150
I
Control of floor drying (
fig. 1, page 38
)
Off
0: Off: Advanced stoppage of the programme running, programme not active
1: Heating functional.
2: Heating ready for occupation.
3: Functional h heating ready.
4: Heating ready + functional heating.
5: Manual: Manual mode enables you to program your own concrete slab drying time.
The function ends automatically after 25 days.
1151
I
Floor curing setpoint manually
(if line 1150 = manual)
0... 95 °C
1 °C
25 °C
This function enables you to set the custom concrete slab drying temperature. This temperature remains fixed.
The concrete slab-drying program stops automatically after running for 25 days.
1156
I
Floor curing day current
0... 32
1157
I
Floor curing day completed
0... 32
0
1200
S
Operating mode changeover
None, Protection mode,
Reduced, Comfort, Automatic
Reduced
Operating mode at end of concrete slab drying period.
Cooling, Circuit 2
(Only available when parameter 5716 is set to “2-pipe system”)
If the installation is fitted with the cooling kit (Only with the cooling kit option).
1201
U
Operating mode
Protection, Automatic, Reduced,
Comfort
Protection
1202
U
Comfort cooling setpoint
17... 40 °C
0.5 °C
24 °C
1203
U
Reduced setpoint
5... 40 °C
1 °C
26 °C
1208
I
Flow temp setp at OT° 25°C
6... 35 °C
0.5 °C
20 °C
Starting cooling temperature setting for an outdoor temperature of 25 °C.
1209
I
Flow temp setp at OT° 35°C
6... 35 °C
0.5 °C
16 °C
Starting cooling temperature setting for an outdoor temperature of 35 °C.
1212
I
Cooling limit at T° ex mixed (8704)
--, 8... 35 °C
0.5 °C
24 °C
If the mixed outside temperature is below this value, the cooling mode is disabled.
1213
S
Lock time at end of heating
--, 8... 100
1 h
24 h
The time delay for operating in cooling mode after having operated in heating mode and vice versa.
Aurea M / Installation / 1883 - EN