50
The water heater must be installed on a smooth and horizontal floor
and must not touch a wall.
Overview
Installation
Use
Maintenance
Warranty
Installation
Regardless of the installation configuration chosen, the installation location must comply with the IP XIB
protection rating, in accordance with the requirements of NFC 15-100.
The floor must support a load of at least 400 kg (surface under the water heater).
Failure to follow the installation recommendations can lead to under-performance of the system.
1. Positioning the product
The water heater must (
in compliance with Article 20 of Standard EN 60335-1
) be fixed to the
ground using the fixing bracket provided for this purpose.
You must install a retention tank under the water heater if it is positioned in an attic or above
inhabited premises.
The identification label
located above the hot
water outlet must be
accessible at all times.
Before filling, the water
heater must be levelled
by
wedging
it
if
necessary.
Attach the water
heater with the
supplied
fixing
bracket.
Minimum height needed from floor to
ceiling to install the product:
200L: 1750mm
270L: 2070mm