5. Technical characteristics
Model
200L
200L C
270L
270L C
Dimensions (Height x Width x Depth)
mm
1617 x 620 x 665
1957 x 620 x 665
Weight empty
kg
80
97
92
111
Tank capacity
L
200
197
270
263
Hot water/cold water connection
-
¾ ʺ M
Anti-corrosion protection
-
ACI Hybrid
Rated water pressure
MPa (bar)
0.8 (8)
Electrical connection (voltage/frequency)
-
230V~ single phase 50 Hz
Total maximum power absorbed by the appliance
W
2500
Maximum power absorbed by the heat pump
W
700
Power absorbed by the electrical backup
W
1800
Setting range of the water temperature set point
°C
50 to 62
Operating temperature range of the heat pump
°C
-5 to +43
Duct diameter
mm
160
Air flow (without duct) in speed 1
m
3
/h
310
Air flow (without duct) in speed 2
m
3
/h
390
Permissible load losses on the air flow
Pa
25
Sound power*
dB(A)
53
Refrigerant R513A
kg
0.80
0.86
Refrigerant volume in equivalent tonnes
T.eq.CO2
0.50
0.54
Refrigerant mass
kg/L
0.0040
0.0032
Certified performance at 7°C air (CDC LCIE 103-15/C) & ducting at 30 Pa**
Coefficient of performance (COP)
-
2,79
2,79
3,16
3,03
Extraction profile
-
L
L
XL
XL
Absorbed power in steady state (P
es
)
W
32
32
28
33
Heating time (t
h
)
h.min
07:52
07:53
10:39
11:04
Reference temperature (T
ref
)
°C
52,7
52,7
53,0
53,1
Air flow rate
m
3
/h
320
320
320
320
* Tested in a semi-anechoic chamber in accordance with the NF 9614-2 standard.
** Performance measured for a water heater from 10°C to T
ref
according to the protocol of the NF Electricity Performance Mark specifications No.LCIE 103-15C, self-
heating thermodynamic water heaters (based on standard EN 16147).
These appliances comply with the 2014/30/EU Electromagnetic Compatibility Directive, the 2014/35/EU Low Voltage Directive, the 2011/65/EU RoHS 2 Directive
and the 2013/814/EU Regulation supplementing Directive 2009/125/EC for Ecodesign.