2. Installation in a non-ducted configuration.
670mm
mini
Overview
Installation
Use
Maintenance
Warranty
9
Unheated location at temperatures above 5°C and isolated from the
heated rooms of the house.
9
"Ducting" setting to be set to "Interior/Interior"
9
Recommended location = underground or semi-underground, room where
the temperature is higher than 10°C all year round.
Leave a space of 500mm in front of the electrical equipment and 300mm in front of the hydraulic
equipment so that the water heater is accessible for its periodic servicing.
Examples of locations:
•
Garage: recovery of free calories released from appliances in operation.
•
Laundry room: Dehumidification of the room and recovery of lost calories
from washing machines and dryers.
Ensure these minimum spaces indicated to avoid recirculating the air.
Interior/Interior
Mini
200mm
Mini
100mm
Mini
200mm
Mini
400mm