1
2
3
5
4
6
7
8
9
10
11
Key:
1. "Liquid" refrigeration connection.
2. "Gas" refrigeration connection.
3.
Heating return (1 circuit).
4.
Heating flow (1 circuit).
5. Stop valve (not provided).
6.
DHW outlet (domestic hot water).
7.
DCW inlet (domestic cold water).
8.
Shut-off (not provided).
9. Filling.
10. Safety valve (mandatory / not supplied).
11. Connections to sewer with siphon
(safety valve).
figure 28 -
Connections
4.3 Filling and bleeding the installation
Check the pipe fixings, tightness of the connectors and
the stability of the hydraulic unit.
Check the direction in which the water is circulating and
that all the valves are open.
Proceed to fill the installation.
Do not operate the circulation pump during filling. Open
all the drain valves in the installation and the bleeder
valve on the hydraulic unit (
P
) to expel the air contained
in the pipes.
Close the drain valves and add water until the pressure
in the hydraulic circuit reaches 1 bar.
Check that the hydraulic circuit has been bled correctly.
Check there are no leaks.
After the
"Commissioning", page 42
stage, and once the
machine has started, bleed the hydraulic unit again
(2 litres of water).
"
Precise filling pressure is determined by the
water pressure in the installation.
figure 29 -
Hydraulic unit manual bleeder valve
P
Installation and Operating Manual "1873- EN"
- 33 -
Alféa Extensa Duo A.I. Heat Pump
Summary of Contents for 024124
Page 17: ... Installation and Operating Manual 1873 EN 17 Alféa Extensa Duo A I Heat Pump ...
Page 29: ... Installation and Operating Manual 1873 EN 29 Alféa Extensa Duo A I Heat Pump ...
Page 81: ... Installation and Operating Manual 1873 EN 81 Alféa Extensa Duo A I Heat Pump ...
Page 86: ... Installation and Operating Manual 1873 EN Alféa Extensa Duo A I Heat Pump 86 ...
Page 87: ... Installation and Operating Manual 1873 EN 87 Alféa Extensa Duo A I Heat Pump ...