4.4 Heating circulation pump
speed settings
figure 30 - Available hydraulic pressures and flow rates
figure 31 -
Operating signals of the HP circulation pump
LED Off:
The circulation pump is not working, no power supply.
Green LED On:
The circulation pump is operating normally.
Green LED flashing:
Venting mode in operation (10 minutes).
Red/green LED flashing:
Operating error with automatic restart.
Red LED flashing:
Operating error.
0
1
2
3
4
5
6
7
8
mCE
1 mbar = 10 mmCE = 100 Pa
m /h
3
1
1,5
2
0,5
0
1
3
55
77
0
1
2
3
4
5
6
7
8
mCE
1 mbar = 10 mmCE = 100 Pa
m /h
3
1
1,5
2
0,5
0
1
3
55
77
Variable pressure
The circulation pump varies the water
pressure depending on the flow rate.
Recommended for an installation fitted with
radiators
(particularly any system with
thermostatic valves or zone solenoids).
Constant pressure
The circulation pump maintains a constant
water pressure whatever the flow rate.
Recommended for an installation with
constant pressure drops such as
an
underfloor heating system
.
Ne pas utiliser cette zone
Do not use these zones
Installation and Operating Manual "1873- EN"
Alféa Extensa Duo A.I. Heat Pump
- 34 -
Summary of Contents for 024124
Page 17: ... Installation and Operating Manual 1873 EN 17 Alféa Extensa Duo A I Heat Pump ...
Page 29: ... Installation and Operating Manual 1873 EN 29 Alféa Extensa Duo A I Heat Pump ...
Page 81: ... Installation and Operating Manual 1873 EN 81 Alféa Extensa Duo A I Heat Pump ...
Page 86: ... Installation and Operating Manual 1873 EN Alféa Extensa Duo A I Heat Pump 86 ...
Page 87: ... Installation and Operating Manual 1873 EN 87 Alféa Extensa Duo A I Heat Pump ...