background image

1

Document No. 98-1724B1 •

 April 2021 • ©2021

 Atlantic Ultraviolet Corporation

®

Owner

s Manual

Owner

s Manual

Amalgam Remote 

Controlled Sanitizer

Installation, 

Operation & 

Maintenance

Read and Follow All 

Safety Instructions. 

Save These Instructions.

UV

Ultraviolet

Radiation

Protect eyes and

skin from direct and

reflected radiation.

DANGER

!

Manufacturers / Engineers / Sales / Service

Germicidal Ultraviolet – Equipment & Lamps

  

375 Marcus Boulevard • Hauppauge, NY 11788 

(631) 273-0500 • Fax: (631) 273-0771

Email: [email protected]

Ultraviolet.com • BuyUltraviolet.com

Extensive Product Information Available at: 

Ultraviolet.com

BuyUltraviolet.com

Summary of Contents for Sanidyne PREMIUM

Page 1: ...ctions Save These Instructions UV Ultraviolet Radiation Protect eyes and skin from direct and reflected radiation DANGER Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 37...

Page 2: ...16 MAINTENANCE LOG 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Premium...

Page 3: ...3 Read and follow all notices and warnings on the sanitizer 14 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product safety labeling...

Page 4: ...or process No warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use The user should p...

Page 5: ...le of Operation The Sanidyne Premium design has been carefully conceived to provide direct germicidal ultraviolet exposure for air and surface disinfection in unoccupied areas to disinfect and prevent...

Page 6: ...nspect all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until Sanidyne Premium is assembled checked and confirmed The Sanidyne Prem...

Page 7: ...tart Stop Button Begins treatment time countdown also used to restart unit after an intruder is sensed in Operating Area 5 Power Indicator Glows RED when power is applied to unit and will flash during...

Page 8: ...te and 30 seconds to exit area b The words LEAVE AREA appear on the lower status bar c Alarm on unit begins to sound d The word PrEP flashes on the Keypad during the Countdown Time when Treatment Time...

Page 9: ...ler 13 ON OFF Button Turns the power to the device on or off and can be used to restart the device To turn on the device this button must be pushed in and held for 2 seconds If the device is on the Ho...

Page 10: ...ment operation will take place It is the users responsibility to post signs or notices for all personnel and persons in the building or facility so that they be made aware that the Operation Area is o...

Page 11: ...than 30 seconds remain on the countdown time the Sanidyne Premium will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area...

Page 12: ...n the display or at the Sanidyne Premiumby pressing the START STOP on the Keypad If the Alarm is turned off at the Sanidyne Premiumthe operator can reset the fixture by pressing the START STOP button...

Page 13: ...r table etc 2 Measure the longest distance from the Sanidyne Premium to the farthest wall Use this length to compare to the Distance From Fixtures Time Minutes shown on Figure 5 below 3 For example if...

Page 14: ...D AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Premium have ArmorLiteTM Safety Shield which is a protective co...

Page 15: ...Surelite Ballast not operating Disconnect the fixture from utility power then replace ballast Sanidyne Premium fails to shut off Microprocessor assembly faulty Wearing protective clothing and face shi...

Page 16: ...side and can be placed in supplied wall holder Uses 1 AAA battery 6 UV C Dosimeter Card 00 0373 Contains a patented colorimetric indicator that changes color at 25 50 and 100 mJ cm2 to visibly confirm...

Page 17: ...17 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Page 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Page 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Page 20: ...including warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the cus...