background image

5

PRODUCT APPLICATIONS 

C

onstruCtion

The 

Sanidyne

®

 

Plus

 Germicidal Ultraviolet Portable Area Sanitizer consists of:

•  STER-L-RAY

®

 

High Output Germicidal Ultraviolet Lamps:

 Deliver ultraviolet energy at the specific wavelength of 254 

nanometers (nm). This wavelength is highly effective against microbes including virus, bacteria and mold spores. Germicidal 

ultraviolet rays are harmful to eyes and skin, avoid exposure of direct or reflected germicidal ultraviolet rays without approved 

ultraviolet blocking face shield and protective covering (such as gloves, long sleeves with no gaps between cuff and gloves).

• 

Audible Exit Warning Alarm:

 To alert area that the lamps will be powered on in one minute and thirty seconds after the start 

button is pressed or to indicate intruder is in Operation Area.

• 

Elapsed Time Indicator:

 A non-resettable display of the operating hours. Useful for scheduling and recording maintenance 

and lamp replacement.

• 

Hand-Held Remote Controller:

 Provides easy operation of 

Sanidyne

®

 

Plus

 from a safe distance, displays lamp operation, 

controls treatment times and alerts operator with an audible alarm if an intruder enters Operation Area.

•  Keypad Controller:

 Provides easy operation of 

Sanidyne

®

 

Plus

 and allows the operator a period of time (one minute and 

thirty seconds) to leave the Operation Area before treatment begins.

•  Intruder Sensors:

 Delay treatment if the Operation Area is inhabited. Additionally if sensors detect an intruder with less than 

30 seconds left before lamps operate, the countdown time will automatically restore back to 30 seconds until area is cleared.

•  Four Wheels with Locking Casters:

 Make moving 

Sanidyne

®

 

Plus

 easily accomplished for location changes.

•  Power Cord:

 For 120v AC 50/60Hz single-phase standard household current, a NEMA 5-15, three-prong plug is provided for 

a properly grounded outlet. 230v AC 50/60Hz models use a CEE 7/7 (Schuko type) plug. (Consult factory for other plug types).

• 

Stainless Steel Lamp Guard Assembly:

 Protects lamps from damage during normal operation.

•  Stainless Steel Construction

: All electronics and wiring are housed in an enclosure constructed of stainless steel, providing 

strength and durability in order to withstand most harsh environments.

•  Sanidyne

®

 

Plus

 will operate between 120v 50/60Hz and 250v 50/60Hz.

P

rinCiPle

 

of

 o

Peration

The

 

Sanidyne

®

 

Plus

 design has been carefully conceived to provide direct germicidal ultraviolet exposure for air and surface 

disinfection in 

unoccupied

 areas to disinfect and prevent areas and surfaces from microorganisms. The ultraviolet disinfection 

dosage is a function of time and the intensity, of the ultraviolet radiation to which the air and surrounding surfaces are exposed.

NOTE:

 The 

Sanidyne

®

 

Plus

 should be used as a supplement to your facility’s cleaning and disinfection protocols, not as a 

replacement.  Follow your facility’s cleaning and disinfection protocols before using the 

Sanidyne

®

 

Plus

No special room preparation is required prior to treating a room or area with the 

Sanidyne

®

 

Plus 

 however, target 

surfaces must be directly exposed to the UV rays. These rays will not penetrate materials like cloth, paper or ordinary glass, 

therefore, it is important to remove items from the direct line of sight that would block or shield the rays from other surfaces. 

The 

Sanidyne

®

 

Plus

 does not generate any harmful byproducts, nor does it leave any residual substances.

It is the user’s responsibility to determine and validate the suitability of the equipment for use in system 

or process. No warranty or representation is made by the manufacturer with respect to suitability or performance of this 

equipment or to the results that may be expected from its use. 

Indoor Use Only – The equipment must be sheltered from exposure to the elements and extremes in 

temperature. Temperature range: 40 °F to 95 °F. The user should periodically inspect, clean as necessary and confirm the 

presence and good legibility of the Product safety labels. Contact the factory for replacement labels in the event that any of 

the labeling is missing or illegible.

The UV Treatment Results achieved are subject to variations in application conditions, it is recommended 

that culture tests be performed to confirm desired outcomes.

l

imitations

•  Safety procedures 

MUST

 be implemented to prevent ultraviolet exposure of occupants to direct or reflected ultraviolet rays. 

Exposure to germicidal ultraviolet rays will result in the irritation of the eyes and reddening of the skin.

• 

Personal protection equipment is required when entering the irradiated space with the germicidal lamp(s) 

operating. Personal protection equipment includes skin and eye protection such as gloves, long sleeves 

with no gaps between cuff and gloves, and an ultraviolet blocking face shield (included with the purchase 

of the 

Sanidyne

®

 

Plus

).

Summary of Contents for G48HO

Page 1: ...tructions Save These Instructions UV Ultraviolet Radiation Protect eyes and skin from direct and reflected radiation DANGER Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Ultraviolet com BuyUltraviolet com Extensive Product Information Available at Ultraviolet com BuyUltra...

Page 2: ...S 16 MAINTENANCE LOG 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Plus Portable Area Sanitizer Questions that are not specifically answerable by these instructions should be directed to the factory Atlantic Ultraviolet Corporation takes all possible precautions when packag...

Page 3: ...13 Read and follow all notices and warnings on the sanitizer 14 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit The following conventions are used to indicate and classify precautions in this manual and on product safety labeling Failure to observe precautions could result in injury to people or ...

Page 4: ... and validate the suitability of this equipment for use in the user s system or process No warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use The user should periodically inspect clean as necessary and confirm the presence and good legibility of the product safety labels Contact the...

Page 5: ...ration The Sanidyne Plus design has been carefully conceived to provide direct germicidal ultraviolet exposure for air and surface disinfection in unoccupied areas to disinfect and prevent areas and surfaces from microorganisms The ultraviolet disinfection dosage is a function of time and the intensity of the ultraviolet radiation to which the air and surrounding surfaces are exposed NOTE The Sani...

Page 6: ...inspect all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until Sanidyne Plus is assembled checked and confirmed The Sanidyne Plus Portable Area Sanitizer includes 1 Eight lamp fixture with power cord Includes a microprocessor controller with time display and push button controls 1 Hand Held Remote Controller 8 STER L RAY High Out...

Page 7: ...Start Stop Button Begins treatment time countdown also used to restart unit after an intruder is sensed in Operating Area 5 Power Indicator Glows RED when power is applied to unit and will flash during Treatment Time Flashes rapidly if occupancy sensor is tripped TREATMENT TIME POWER MINUTES HOURS START STOP Treatment Time Displays HOURS MINUTES 1 Hours Button Up and Down Arrows set time from 0 to...

Page 8: ...ute and 30 seconds to exit area b The words LEAVE AREA appear on the lower status bar c Alarm on unit begins to sound d The word PrEP flashes on the Keypad during the Countdown Time when Treatment Time begins the word run flashes and when the treatment time is completed the word donE will appear 6 Return Button Brings you back to previous screen Remote Overview Continued on Page 9 Lamp operation i...

Page 9: ...ller 13 ON OFF Button Turns the power to the device on or off and can be used to restart the device To turn on the device this button must be pushed in and held for 2 seconds If the device is on the Home screen pressing and holding this button will bring up a menu with choices to Power Off Reboot Airplane Mode ON OFF MUST BE SET TO ON AT ALL TIMES Additionally displays three icons at bottom which ...

Page 10: ...ent operation will take place It is the users responsibility to post signs or notices for all personnel and persons in the building or facility so that they be made aware that the Operation Area is off limits during treatment 3 Connect the Sanidyne Plus to a properly grounded outlet power source which matches the power requirements listed on the Sanidyne Plus See Power In location shown on Figure ...

Page 11: ... than 30 seconds remain on the countdown time the Sanidyne Plus will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area of the Sanidyne Plus Under no circumstances should this sanitizer be permitted to operate with humans plants or animals present in the Operation Area 4 Outside the Operation Area the Treatment Time can...

Page 12: ...he display or at the Sanidyne Plusby pressing the START STOP on the Keypad If the Alarm is turned off at the Sanidyne Plus the operator can reset the fixture by pressing the START STOP button on the keypad controller again to begin the 1 30 countdown to allow all inhabitants to leave the area After the 1 30 has elapsed the Sanidyne Plus will power on and complete the remaining Treatment Time left ...

Page 13: ...able etc 2 Measure the longest distance from the Sanidyne Plus to the farthest wall Use this length to compare to the Distance From Fixtures Time Minutes shown on Figure 5 below 3 For example if the distance from your fixture measures 15 feet find the 15 foot mark on the bar chart for each time range As the treatment time increase dose increases NOTE The number at the end of each bar is the expect...

Page 14: ... AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Plus have ArmorLiteTM Safety Shield which is a protective covering over the glass of the lamp DO NOT REMOVE this covering Always disconnect power to the fixture before performing any service or maintenance Germicidal lamps are easily damaged Exercise care when han...

Page 15: ...properly seated Check lamp socket and re install lamp if necessary Loose Connection Inspect for loose or disconnected wires Surelite Ballast not operating Disconnect the fixture from utility power then replace ballast Sanidyne Plus fails to shut off Microprocessor assembly faulty Wearing protective clothing and face shield enter area and disconnect power to unit Call factory for technical service ...

Page 16: ...d can be placed in supplied wall holder Uses 1 AAA battery 6 UV C Dosimeter Card 00 0373 Contains a patented colorimetric indicator that changes color at 25 50 and 100 mJ cm2 to visibly confirm that your Sanidyne Plus is achieving the desired UV C exposure Each card is designed for one 1 treatment cycle and CANNOT be reused Complete instructions for use are on back of card One 1 card has been incl...

Page 17: ...17 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Page 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Page 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Page 20: ...lied including warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or to any person for injury to person damage to or loss of property or value caused by any product which has been subjected to misuse negligence accident or modified or repaired by unauthor...

Reviews: