background image

 

ATIM_ACW-TCR_UG_EN_V1.0 

This user guide applies to the below product versions 

 

 

 

 

Document version history 

 

Version 

Date 

Description 

Auteur 

Concerned 
software 
version 

0.1 

02/06/2020 

First document version 

YLB 

V0.0.1 

0.2 

12/11/2020 

Keep  alive  frame  description,  add  pairing 
mode,  update  error  code  table,  update 
configurator images 

AC 

V0.0.1 

0.3 

10/12/2020 

Downlink  frame  and  datalogging  description 
correction 

AC 

V0.0.1 

1.0 

07/05/2021 

Casing modification 

AC 

V1.0.2 

 

Disclaimer  

The information contained in this document is subject to change without warning and does not represent a 
commitment on the part of ATIM.  

Trademarks and copyright  

ATIM,  ACW  ATIM  Cloud  Wireless

® 

and  ARM  Advanced  Radio  Modem

® 

are  registered  trademarks  of  ATIM  SARL  in 

France. The other trademarks mentioned in this document are the property of their respective owners.  

 

 

Product references  

 
Product  version  (Visible  on 
the product label)  

LoRaWAN

 

ACW/LW8-TCR 

A.0 

Sigfox 

ACW/SF8-TCR 

A.0 

Summary of Contents for Atim Cloud Wireless ACW/LW8-TCR

Page 1: ...iocommunications Chemin des Guillets 38250 Villard de Lans France www atim com info atim com Atim Cloud Wireless Temperature humidity monitoring Cold room User Guide Mod les concern s ACW LW8 TCR ACW...

Page 2: ...DIO MODULE ACTIVITY 12 F THRESHOLD EXCEEDED 13 G ANTI FRAUD SYSTEM 13 H SUBSTITUTION TO THE MAGNET 13 I BATTERY PASSIVATION 13 ACW CONFIGURATOR 14 A COMPATIBLE CONFIGURATOR VERSION 14 B CONFIGURATION...

Page 3: ...ent 27 DOWNLINK 28 A CONFIGURATION OF THE FRAME PARAMETERS SENDING PERIOD NUMBER OF SAMPLES ETC 28 B VIRTUAL PROBE CONFIGURATION 28 C NUMBER OF PROBES 29 D THRESHOLD CONFIGURATION 29 E RESERVED CODES...

Page 4: ...atalogging description correction AC V0 0 1 1 0 07 05 2021 Casing modification AC V1 0 2 Disclaimer The information contained in this document is subject to change without warning and does not represe...

Page 5: ...y spectrum Art 3 2 of the 1999 5 EC Directive ETSI EN300 220 2 v2 4 1 and EN300 220 1 v2 4 1 Environmental recommendations a Explosive environment Except for the ACW ATEX range intended for this use d...

Page 6: ...s symbol appears on a product or its packaging to indicate that the product may not be discarded with other household waste Rather it is your responsibility to dispose of this product by bringing it t...

Page 7: ...mast DIN Rail Casing IP 65 Power Supply 1 battery packs 7 2 Ah Weight 200 g Frequency 863 870 MHz Power 25 mW 14 dBm Rate Sigfox 100 bits s LoRaWAN 300 bit s 10 Kbit s Consumption Sigfox LoRaWAN Tx m...

Page 8: ...ation ACW THO modems are fixed to a flat wall using the 4 fixing holes available at each corner of the case Install the modem at a minimum height of 2m and not glued to the wall ideally offset at leas...

Page 9: ...UG_EN_V1 0 For best results it is advisable to place it high up and free from any metallic obstacle within a radius of 1 meter if possible see figures below For information the antenna is integrated i...

Page 10: ...rd inside and in the status bar in the ACW configuration tool For LoRaWAN modems the communication keys are automatically provided by the network pairing via Over The Air Activation or OTAA TCR Etique...

Page 11: ...it via Downlink Pairing mode this mode is active after exiting dee sleep mode and allows to pair to the network Fault mode This mode allows the normal operation of the module to be interrupted when a...

Page 12: ...ary to provision a Downlink It is this that will determine the quality of the network The product emits at startup directly for Sigfox after the Join phase for LoRaWAN a test Uplink described in the C...

Page 13: ...perform the same actions as the magnet activate or standby the product activate deactivate Bluetooth To do this open the box and press the push button twice at the same time A white flash indicates t...

Page 14: ...urator is launched the waiting window appears on the screen Click on Help at the top left of the window then on About to display the version number of the ACW configurator Pairing the ACW TCR with the...

Page 15: ...ment will be made every 3 minutes and the 4 samples will be sent in a single frame every 12 minutes Finally it is possible to apply a redundancy of the data 3 which means that samples having been sent...

Page 16: ...lues are calculated by averaging the x last values from the physical probe According to this the parameters are 8 Enabling and disabling both virtual and physical probes The value of the inertial coef...

Page 17: ...radio frame 10 minutes Number of samplings 1 History depth 1 General settings Emission period of the keep alive frame 4 days Timestamp disabled Sensor s configuration Probe 1 physical State enabled Th...

Page 18: ...TIM_ACW TCR_UG_EN_V1 0 d Update ACWs When connected with Bluetooth Low Energy to the product it is possible to update the different software that composes it To do this go to the menu Tools Updater CT...

Page 19: ...each of the channels that an ACW can read Beforehand the number of samples and the depth of the history will be inserted in the header Notes The number of samples and the depth of the history are in...

Page 20: ...ample of each of the alert channels 0x0e TBD General error TBD memory 0x0f Variable Subframe for ACW In function of the ACW product Measuring frame If the Timestamp is enabled 4 bytes with the Timesta...

Page 21: ...oduct The number of bytes sent can be determined as follows Size in bytes of the measurement number of samples history depth Alert frame If the Timestamp is activated 4 bytes with the Timestamp value...

Page 22: ...e is therefore split as follows 0xAABBBBCCCC 0xAA being the frame header always equal to 0x81 0xBBBB the empty battery level value in millivolts MSB coding and 0xCCCC the charging battery level value...

Page 23: ...ement in the frame header is too large or too small 0x87 ERR_SAMPLING_PERIOD Bad structure of sampling period 0x88 ERR_SUBTASK_END End of a sub task after leaving an infinite loop 0x89 ERR_NULL_POINTE...

Page 24: ...will enter its FAULT mode and will no longer perform its measurement function For codes ranging from 0x93 to 0x9D these correspond only to alarms so the product continues to operate normally 0x99 ERR...

Page 25: ...measurement humidity 0x17 0xDE 0x18 channel 1 virtual type of measurement temperature 0x01 0x2C 0x19 channel 1 virtual type of measurement humidity 0x21 0x54 The probe on channel 0 returns 0x0885 21...

Page 26: ...0x09 chann el 0 type of measur ement humidit y 0x22 0x13 0x17 0xDE 0x18 channe l 1 virtual type of measur ement temper ature 0x01 0x38 0x01 0x86 0x19 channel 1 virtual type of measure ment humidity 0x...

Page 27: ...high threshold exceeded on channel 1 virtual probe the frame will be Byte 1 Byte 2 Byte 3 Byte 4 0x8D new generation alert frame 0x58 high threshold channel 1 exceeded temperature measurement 0x02 0xC...

Page 28: ...alue Byte 2 Parameter value Byte 3 Parameter value Byte 4 0x94 0b00YY0ZZZ 0xYY 0xZZ For byte 2 the two bits YY correspond to the history depth max 3 and the three bits ZZZ correspond to the number of...

Page 29: ...perature threshold probe 1 0xD6 temperature threshold probe 2 0xD7 humidity threshold probe 1 0xD8 humidity threshold probe 2 Upper threshold value Lower threshold value Hysteresis Length High thresho...

Page 30: ...30 ATIM_ACW TCR_UG_EN_V1 0 e Reserved codes for futures evolutions Parameter code Byte 1 Parameter value Byte 2 0x10 0x08 0x11 0x00 WARNING DO NOT CHANGE THESE VALUES...

Page 31: ...31 ATIM_ACW TCR_UG_EN_V1 0 Technical support Contact our technical support team by email with any questions or technical problems you may have https www atim com en technical support...

Reviews: