UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
17
Ed 2021-02
17.
TRUNK GAS
Connect the gas supply line of the thread, present on the appliance, by means of a removable rigid connector: the pipe must exit
through the slot of the appliance. The attack gas connection is G 1/2 ": it is recommended to mount along the pipe, in the
vicinity of the generator and in an easily accessible location, a faucet interception manual gas. See in the figure below, the gas
attack and the slot of the tube passage.
Check the tightness of the gas pipe and make sure that it has been performed in accordance with regulations on gas system
(seeLOCAL REGULATIONS, AND INSTALLATION OF SAFETY).
18.
ELECTRICAL CONNECTIONS
The machine is sold without mains plug: CPU must be mounted to the first installation.
Connect electrically to a power network at 230V-50Hz, single phase, and to an effective grounding. E 'need to perform a
polarized connection. The appliance cable is composed of three distinct colors cables (refer to the table below to identify the
correct polarization).
Connect the power cord of the appliance, taking care to comply with the electrical standards of the country in which the
appliance is installed. If the power cord is damaged, it must be replaced by a technical service center authorized by the
manufacturer, or by a similarly qualified person in order to avoid a hazard. For the eventual stopping of the appliance, in the
feeding of the same network is necessary to provide a disconnect device (not supplied) with an opening distance of the contacts
that allows complete disconnection in the conditions dictated by the overvoltage category III
LINE AND NEUTRAL PLUG TO BE THE SAME AS LINE AND NEUTRAL THE ELECTRICAL OUTLET.
Neutral
Line
green yellow
blue
Brown
Assemble the apparatus in the vicinity of an isolating switch for the eventual general stopping of the appliance. This disconnect
device must be incorporated in the supply system in accordance with installation rules. Connect the power cord of the
appliance, taking care to comply with the electrical standards of the country in which the appliance is installed. In case of
replacement of the electric power cable, use only a cable with the same characteristics (cable H05 VV-F - 3x0.75).
Warning: The device has no protection against the effects caused by lightning. Before accessing any electrical part of the
appliance, remove the power supply using the bipolar switch.
INSTALLATION AND 'FINISHED, THE UNIT AND' READY TO BE LIT AND REGULATED.