EXHAUST FUMES
The installation of the exhaust terminals must comply with the regulations in force.
In any case, any provisions foreseen by municipal, provincial or sectorial regulations must be respected. The flue gases of several
boilers must not be conveyed inside the same flue gas exhaust pipe: each boiler must have its own independent exhaust pipe.
The boiler is supplied as standard without exhaust kit. The following table shows the kits available for this appliance. Use only
the original kits (to be purchased separately depending on the type of exhaust you want to make) supplied by the manufacturer.
SMOKE EXHAUST KIT
COMPOSITION
LIMITS
APPLICATION
AKIT21
Horizontal coaxial drain Ø60 /
100
Material: White aluminum
C1
Min 1m
Max 3m
AKIT22
Split horizontal exhaust Ø80 / 80
Material: White aluminum
C4, C5, C8
Min 1m + 1m
Max 6m + 6m
AKIT23
Vertical coaxial discharge
Ø60 / 100
Material: White aluminum
C3
Max 1m
AKIT24
Vertical coaxial exhaust Ø80 /
125
Material: stainless steel
C3
Min 1m vertical
Max 4m vertical
Min 0m horizontal
Max 1m horizontal
AKIT25
Horizontal single wall drain Ø80
Material: stainless steel
B5
Min 1m horizontal
Max 6m horizontal
AKIT26
Vertical double wall drain Ø80 /
130
Material: stainless steel (inside))
Black painted aluminum (outside)
Insulation: rock wool
B5
Min 1m horizontal
Max 6m horizontal
Min 1m vertical
(including terminal)
Max 5m vertical
(including terminal)