UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
20
Ed 2021-02
Models
SX220
SX300
SX400
SX600
SX800
1)
Switch off the appliance, close the gas interception valve and disconnect the power supply
2)
Remove the burner door (A) and the insulating material (B)
3)
Unscrew the gas pipe (E)
TRANSFORMATION OF GAS SUPPLY
TO PROPANE G31
TRANSFORMATION OF GAS SUPPLY
TO METHANE G20
4)
SX300 / SX400 / SX600 / SX800 models only:
unscrew the screws (D) and replace (or remove
for SX800) the two slot closing plates (C) with
those present in the gas conversion kit. The
opening must remain in the lower part
5)
Unscrew the 4 screws (F), position the mask
(G) in front of the burners and tighten the
screws (F)
4)
SX300 / SX400 / SX600 / SX800 models only: unscrew
the screws (D) and replace (or insert for SX800) the
two slot closing plates (C) with those present in the
gas conversion kit. The opening must remain in the
lower part
5)
Unscrew the 4 screws (F), remove the mask (G)
in front of the burners and retighten the screws
(F)
6)
Replace the injectors (H). Be careful not to lose the sealing washers
7)
Connect the gas pipe (E)
8)
Start up the appliance and check the tightness of the gas circuit with a special spray
9)
Adjust the burner pressure, according to the indicated value, using the REG screw on the gas valve. The P.OUT
pressure point can be used to check the value
10)
Put the burner door (A) and the insulating material (B) back in their original positions and tighten with the
fixing screws.
11)
Attach the label contained in the kit to indicate the new type of gas supply.
IMPORTANT:
CHECK THE SEALING OF THE GAS PIPES, SCREWS AND JOINTS BEFORE TURNING THE APPLIANCE ON. THE WORN GASKETS MUST
NOT BE REUSED, IT IS COMPULSORY TO REPLACE THEM WITH NEW PARTS SUPPLIED WITH THE CONVERSION KIT.