UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
14
Ed 2021-02
To increase the drain length it is necessary to purchase the appropriate extensions proposed in the following table. The
maximum supported extension is shown in the previous table. Each curve is equivalent to 1 meter of the total length.
The choice of the type of drain must take into account local and national regulations.
EXHAUST FUMES KIT
DESCRIPTION
CODE
AKIT21
Coaxial horizontal drain Ø60 / 100
Coaxial extension Ø60 / 100 L = 500
AIPC05
Coaxial extension Ø60 / 100 L = 1000
AIPC10
Coaxial bend Ø60 / 100 at 45 °
AICC45
Coaxial bend Ø60 / 100 at 90 °
AICC90
AKIT22
Split horizontal drain Ø80 / 80
Extension Ø80 L = 250
AIPR802
Extension Ø80 L = 500
AIPR805
Extension Ø80 L = 1000
AIPR80
Curve Ø80 at 45 °
AICV804
90 ° bend Ø80
AICV809
AKIT24
Vertical coaxial drain Ø80 / 125
Coaxial bend Ø80 / 125 45 °
AKIT24-01
Coaxial extension Ø80 / 125 L = 500
AKIT24-02
Coaxial extension Ø80 / 125 L = 1000
AKIT24-03
Adjustable wall collar Ø125 Inox
AKIT24-04
Coaxial extension Ø60 / 100 L = 1000
AIPC10
AKIT25
Single wall horizontal drain Ø80
Extension Ø80 L = 500
AKIT25-01
Extension Ø80 L = 1000
AKIT25-02
Curve Ø80 at 45 °
AKIT25-03
90 ° bend Ø80
AKIT25-04
AKIT26
Double wall vertical drain Ø80 / 130
Horizontal extension Ø80 L = 500
AKIT25-01
Horizontal extension Ø80 L = 1000
AKIT25-02
Double wall vertical extension Ø80 / 130 L = 500
AKIT26-01
Double wall vertical extension Ø80 / 130 L = 1000
AKIT26-02
Double wall bend Ø80 / 130 45 °
AKIT26-03
Wall support
AKIT26-04
Make sure you have always guaranteed the mechanical stability of the duct.
The hole, for the passage through the wall of the exhaust and air intake pipe,
must not be concreted: the flue gas exhaust must be free to slide through the
hole so that it can be extracted later.
For this purpose, the wall cover rosettes supplied with the flue gas exhaust kit
can be used to cover the empty space of the hole.
IMPORTANT:
LEAVE A SPACE NOT LESS THAN 30 CM ABOVE THE APPLIANCE TO ALLOW ANY MAINTENANCE INTERVENTION ON THE UPPER
PART.
TO AVOID POSSIBLE WATER INFILTRATION DURING THORMS, WE RECOMMEND A SLIGHT SLOPE DOWNWARDS OF THE AIR
INTAKE AND EXHAUST PIPE.
DIAPHRAGM
For correct operation of the appliance it is mandatory to install the diaphragm A contained in the exhaust kit together with the
additional gasket B on the intake duct.