Manual, F/T Sensor, Ethernet Axia
Document #9610-05-Ethernet Axia-09
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
74
Table 9.4
—config.cgi Variables
Variable Name
Allowed
Values
Description
cfgtfx0
Floating point
Sets the tool transformation distance D
x
with the units that are specified
in the variable: cfgtdu.
cfgtfx1
Sets the tool transformation distance D
y
with the units that are specified
in the variable: cfgtdu.
cfgtfx2
Sets the tool transformation distance D
z
with the units that are specified
in the variable: cfgtdu.
cfgtfx3
Sets the tool transformation distance R
x
with the units that are specified
in the variable: cfgtau.
cfgtfx4
Sets the tool transformation rotation R
y
with the units that are specified
in the variable: cfgtau.
cfgtfx5
Sets the tool transformation rotation R
z
with the units that are specified
in the variable: cfgtau.
9.5 CGI Variable: Communications (comm.cgi)
A user can set the networking options of the sensor (refer to
Section 6.7—Communication Page (comm.htm)
for more information).
Table 9.5—comm.cgi Variables
Variable Name
Allowed Values
Description
comnetdhcp
Integers: 0 or 1
Sets DHCP behavior.
Value
Description
0
Use DHCP if available on network
1
Use software-defined static IP values
comnetip
Any IPV4 address
in dot-decimal
notation.
Sets the static IP address to be used when DHCP is disabled.
comnetmsk
Any IPV4 subnet
mask in dot-
decimal notation.
Sets the subnet mask to be used when DHCP is disabled.
comnetgw
Any IPV4 address
in dot-decimal
notation.
Sets the gateway to be used when DHCP is disabled.
comrdtbsiz
Integers: 1 to 40
RDT Buffer Mode buffer size.