background image

27

SL1 DATA LOGGER User Manual Rev. AD

[email protected]

www.getdata.it

ENGLISH

• 

The new archive folder will be shown in the Run files Destination box:

For the archive path: Track name, Session and Vehicle will influence the path of the data storage 

folder as follows:

Base directory \ Track \  Session  \ Vehicle Name \ Run_name\...file downloaded

Where:

Base directory: this is the main folder for the storage path - set on the

DATA page (se

chap. 12.2

).

Track: this is the first subfolder of the storage path – its value is set by the

Track name on the setup INFO panel.

Session: this is the second subfolder of the storage path – its value is set by the

Session on the setup INFO panel.

Vehicle Name: this is the third subfolder of the storage path – its value is set by the

Vehicle on the setup INFO panel.

Run_name: this is the last subfolder of the storage path – its value is set by

“Run_“ followed by the progressive number of the session created by the SL1 Data Logger.

For more information, refer t

chapter 1 Annex 1

Summary of Contents for GET SL1

Page 1: ...ENGLISH DATA LOGGER User Manual...

Page 2: ...getdata it ENGLISH The content of this document nor parts of it may be reproduced transferred distributed or stored in any form without the written permission of GET by Athena GET reserves the right...

Page 3: ...data Run 28 12 4 Deleting the acquired data Run 29 12 5 Opening saving and modifying the setup 30 12 5 1 Downloading the setup from SL1 31 12 5 2 Open the setup file set 32 12 5 3 Sending the setup t...

Page 4: ...omised track 70 9 2 Sending a track to the SL1 Data Logger 74 ANNEX 2 PINOUTS 78 1 MAIN CONNECTOR 78 2 EXP CONNECTOR 78 3 USB CONNECTOR 79 ANNEX 3 CONNECTING THE SL1 WIRING 80 1 MAIN POWER IC WIRING c...

Page 5: ...t can help you to properly use your new GET by Athena device Thanks to GPS technology the devices in the SL1 Data Logger family are able to acquire not only signals from the sensors connected to them...

Page 6: ...g inertial sensors LED Light Emitting Diode the luminous lights on the SL1 Data Logger LOGGER DATA LOGGER SL1 Data acquisition system LynXLog Software for managing the SL1 Data Logger OTA Software upd...

Page 7: ...athena eu www getdata it ENGLISH 1 SL1 KIT The SL1 kit includes SL1 Data Logger 1 GPS Antenna 1 SL1 wiring harness 1 USB flash drive 1 USB data cable mini USB for connection to the PC Note The conten...

Page 8: ...tes it is possible to identify the 3D position of the receiver 24 GPS satellites in orbit inclined 55 degrees with respect to the equator are located between 18000 and 20000 km from the earth and rota...

Page 9: ...then displayed by the software are compromised Evidence of this are quick changes in vehicle position spikes also in the order of Km 4 NECESSARY REQUIREMENTS The following is required to acquire data...

Page 10: ...tions and trajectories Do not twist the antenna cable with other cables especially around high voltage cables this could cause inductive interference and therefore problems during operation Do not pas...

Page 11: ...to damage them Install the system when the engine is cold during installation it could come into contact with hot parts Carefully handle the connectors and wiring avoid contact with sharp or hot surfa...

Page 12: ...lick the file and follow the instructions that appear on the screen If you want to install the software manually follow these instructions Accept the terms of the license and then press Next Proceed a...

Page 13: ...13 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH Leave all the selected components and press Next...

Page 14: ...14 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH Proceed with the installation following the instructions shown in the following windows 1 LynXLog...

Page 15: ...15 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH 2 Driver...

Page 16: ...16 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH 3 WinTAX 4 Finish...

Page 17: ...tware updated LynXLog uses an Ota over the air update method When LynXLog is started it checks if there are any updates using the PC internet connection If there are updates LynXLog will download them...

Page 18: ...sk to update it Once the transfer is complete the software will ask for confirmation to update the SL1 Data Logger If you press Yes SL1 will be updated and when the update process is complete it will...

Page 19: ...WinTAX4 JUNIOR ACTIVATION ARCHIVE FOLDER SETTING Base Directory INSTALLATION OF SL1 DATA LOGGER IN THE VEHICLE CONNECT SL1 DATA LOGGER TO PC CONFIGURE THE ACQUISITION PARAMETERS CHANNELS TRIGGERS INFO...

Page 20: ...PS OFF GPS signal OK Green GPS Flashing GPS signal search Yellow SYSTEM ON System ready Yellow SYSTEM Flashing Acquisition in progress Red DIAGNOSTICS OFF System OK Red DIAGNOSTICS Flashing System in...

Page 21: ...data in the PC for analysis Configure the acquisition parameters properties of the channels log triggers etc Configure the system parameters e g LED brightness or GPS dynamics See the home page of Lyn...

Page 22: ...n be downloaded deleted and the destination folder can be set LOG CONFIG Opens the acquisition configuration page where it is possible to change the properties of the channels log triggers etc MONITOR...

Page 23: ...ery The SL1 Data Logger can be connected in two ways Via USB code GK SL1 0001 and GK SL1 0002 Via WiFi only code GK SL1 0001 12 1 1 USB CONNECTION Proceed as follows to connect the SL1 Data Logger via...

Page 24: ...d WiFi connection GK SL1 0002 which only has a USB connection If a GK SL1 0002 is purchased it is not possible to follow the instructions in this chapter because a GK SL1 0001 is required Connect the...

Page 25: ...v AD sales get athena eu www getdata it ENGLISH Open the Windows network manager Select the ssid of the SL1 Data Logger to which you want to connect Enter the WIFI password which can be found on the l...

Page 26: ...will save all the downloaded data sessions in a specific Base Directory folder The user can change the predefined folder located in Documents WinTAXWorkspace by opening the DATA page Procedere come se...

Page 27: ...path set on the DATA page see chap 12 2 Track this is the first subfolder of the storage path its value is set by the Track name on the setup INFO panel Session this is the second subfolder of the sto...

Page 28: ...he SL1 Data Logger by following these instructions Connect the SL1 Data Logger to the PC see chapter 12 1 Open the Data page by pressing the Data button or pressing the icon on the navigation bar Pres...

Page 29: ...saved acquired data can be deleted from the SL1 Data Logger as follows Connect the SL1 Data Logger to the PC see chapter 12 1 Open the Data page by pressing the Data button or pressing the icon on the...

Page 30: ...ollowing options The information set such as vehicle name pilot etc used to identify the Run after the download The method for starting acquisition Which of the signals connected to the physical input...

Page 31: ...ded as follows Connect the SL1 Data Logger to the PC see chapter 12 1 Open the setup configuration page by pressing the Log Config button or pressing the icon on the navigation bar Press the button Re...

Page 32: ...ta Logger with the following procedure Run LynXLog Open the acquisition configuration page by pressing the Log Config button or pressing the icon on the navigation bar Press the Open Conf button to op...

Page 33: ...ollows Connect the SL1 Data Logger to the PC see chapter 12 1 Make sure that the correct setup was loaded see chapter 12 5 1 and 12 5 2 Press Set Conf to send the setup to the SL1 Data Logger During t...

Page 34: ...ysical input channels ordered by function ANALOG AN1 AN2 AN3 EXP connector DIGITAL IC1 on the MAIN connector CAN PORT GET CAN Bus port 1 on the MAIN connector CAN PORT AUX CAN Bus port EXP on the EXP...

Page 35: ...H 12 5 5 SAVING THE SETUP TO A FILE SET Press the Save Conf button in the Actions column Select the folder where the setup file should be saved select the name and then press save Once the change to t...

Page 36: ...Data Logger to the PC see chapter12 1 Open the page by pressing the Monitor function button or by pressing the icon on the navigation bar Press the box next to the channel you want to see in real tim...

Page 37: ...LAYING A CHANNEL IN REAL TIME Press the Monitor button in the actions column At this point the current value of the channel will be displayed It changes in real time as the input signal changes Repeat...

Page 38: ...6 3 REMOVING A CHANNEL FROM THE CHANNEL MONITOR LIST To remove a channel from the channel monitor list press the button to the left of the name of the channel Another way to remove the channel from th...

Page 39: ...ENGLISH 12 6 4 CALIBRATING A CHANNEL ON THE CHANNEL MONITOR LIST To calibrate a channel on the Channel Monitor list press the button More information about calibration is available in chapter 6 of Ann...

Page 40: ...the type of channel as suspension and select the length of the sensor stroke see 6 4 3 Make sure that the suspension is in the correct zero position 4 View the channel in real time see chapter 12 6 2...

Page 41: ...t acquisition Connect the SL1 Data Logger to the PC see chapter 12 1 Open the Data page by pressing the Data function button or by pressing the icon on the navigation bar Press the Man Rec button in t...

Page 42: ...SL1 Data Logger by pressing the Power Off button Display the information for the SL1 Data Logger firmware version etc by pressing INFO in the System options column Synchronise the system clock of the...

Page 43: ...It is possible to change the auto power off time for the SL1 Data Logger If the SL1 Data Logger is not in acquisition mode is not connected to a PC and is not powered by an external power supply it w...

Page 44: ...OGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH Select a time option from among those available and then press Set Device in the Actions column to send the configuration to the SL1...

Page 45: ...es get athena eu www getdata it ENGLISH 12 8 2 CHANGING THE GPS DYNAMIC To improve the GPS trajectories it is possible to select the GPS dynamic that best suits to the type of trajectory being acquire...

Page 46: ...OGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH Press one of the available icons to select the dynamic Press Set Device in the Actions column to send the changed dynamic to the SL1...

Page 47: ...et athena eu www getdata it ENGLISH 12 8 3 CHANGING THE BRIGHTNESS OF THE SL1 LEDs Proceed as follows to adjust the brightness of the LEDs on the SL1 Press LEDs in the System options column Press one...

Page 48: ...y an external power supply it will turn off automatically after the Auto power off time this time can be changed on the SYSTEM page If the residual charge of the battery in the SL1 Data Logger is insu...

Page 49: ...TTINGS Press the LynXLog Setup function button to access the Lynxlog settings Or press the icon in the navigation bar If you want to change the size of the LynXLog text press TEXT SIZE in the Software...

Page 50: ...u want to change one of the following folders Data Archive base folder Track Archive predefined folder for the tracks Log Config Archive predefined folder for the SL1 Data Logger configurations This c...

Page 51: ...A LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH Press one of the paths you want to change to select it A window will open where the desired folder can be selected Confirm it onc...

Page 52: ...Acquisition status LED GPS antenna connector SMA Type of casing high resistance plastic Mechanical dimensions 21mm x 62mm x 79mm without cables and antenna connector Weight 167g IP degree IP 67 Firmw...

Page 53: ...see chapter 12 5 1 and 12 5 2 SL1 configuration GROUP CATEGORY DESCRIPTION RELATED TO INFO Information about the track the pilot Archiving TRIGGERS Acquisition start stop rules Acquisition AN FRQ ANAL...

Page 54: ...necessary configurations and save the setup or send it to the SL1 Data Logger when finished For the archive path Track name Session and Vehicle will influence the path of the data stora ge folder as f...

Page 55: ...HING FOR A CHANNEL There is a search function that makes it easier to search for a channel in the Config Channel Tree Press the text in the Find Channel field and scroll the list of all the channel na...

Page 56: ...efault press TRIGGERS and select the desired channel from the drop down menu NOTE the list of channels varies based on the available configured channels If the channel selected for starting acquisitio...

Page 57: ...Log frq the acquisition frequency if this parameter is set to None the channel will not be acquired and will not be available for software analysis Decimals the number of decimals to be displayed Unit...

Page 58: ...of the data buses and the related channels To add a new channel press Add Channel in the Config Channel Tree column Here it is possible to set the following properties of a CAN port Bus Speed this pa...

Page 59: ...tered with or without the prefix 0x it is not relevant ID Type defines the type of identifier standard ID length 11 bits or extended length length of the ID up to 29 bits NOTE normally the ID below 0x...

Page 60: ...ameter sets the format of the data to one of the following Intel Little Endian byte order Motorola Big Endian byte order NOTE this option is only available for channels with a bit length greater than...

Page 61: ...NEL To configure a channel press the name in the Config Channel Tree column or press the Edit button in the CAN PORT GET column The Channel Calibration window will open OR Configure as necessary and s...

Page 62: ...l not be calibrated and will be acquired as is raw format Linear the input data will be calibrated linearly using a gain and offset Polyline the input data will be calibrated using a multipoint calibr...

Page 63: ...be set Press the gain field to enter the desired gain value Press the offset field to enter the desired offset value ATTENTION THE NEW CONFIGURATION IS NOT YET SAVED SAVE IT TO A FILE OR SEND IT TO T...

Page 64: ...Values table must be filled in according to the following method Each value in the Raw Value column must have the corresponding value in the Cal Value column where The Raw Value is the raw value read...

Page 65: ...65 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH To add a new line press To remove the last line of values press...

Page 66: ...NGLISH ATTENTION THE NEW CONFIGURATION IS NOT YET SAVED SAVE IT TO A FILE OR SEND IT TO THE SL1 DATA LOGGER SEE CHAPTERS 12 5 3 AND 12 5 5 TO SEND THE NEW CALIBRATION TO THE SL1 DATA LOGGER PRESS THE...

Page 67: ...LIBRATION SUSPENSION If the sensor to calibrate is a suspension this type of calibration must be used Press Sensor stroke to enter the length of the useful working area of the sensor expressed in mm C...

Page 68: ...NGLISH ATTENTION THE NEW CONFIGURATION IS NOT YET SAVED SAVE IT TO A FILE OR SEND IT TO THE SL1 DATA LOGGER SEE CHAPTERS 12 5 3 AND 12 5 5 TO SEND THE NEW CALIBRATION TO THE SL1 DATA LOGGER PRESS THE...

Page 69: ...by pressing GPS once in the Config Channel Tree column This panel displays the GPS channels logged by the SL1 Data Logger The IMU panel can be opened by pressing IMU in the Config Channel Tree IMU col...

Page 70: ...NAGEMENT 9 1 CREATING YOUR CUSTOMISED TRACK Make sure that the PC has an internet connection Run LynXLog and press the Track function button Press Click here to search and enter the name of the city o...

Page 71: ...AD sales get athena eu www getdata it ENGLISH Press Add Line in the Actions column this will make it possible to create a Finish Line Move the map near the finish line if necessary and press it to po...

Page 72: ...t athena eu www getdata it ENGLISH Press the map to create the second finish line point A finish line will appear with a green arrow indicating the direction of the race If the direction is incorrect...

Page 73: ...73 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH Enter the name for the track in the Track Name field Press Save Track in the Actions column to save the track...

Page 74: ...get athena eu www getdata it ENGLISH 9 2 SENDING A TRACK TO THE SL1 DATA LOGGER Connect the SL1 Data Logger to the PC and wait for it to be recognised by Lynxlog see chapter 12 1 1 Press the Log Conf...

Page 75: ...75 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH Press the Read Conf button in the Actions column to download the setup from the SL1 Data Logger...

Page 76: ...t ENGLISH Press TRIGGERS in the Config Channel Tree column the DATA LOG TRIGGERS table and the LAP TRIGGER SOURCE table will appear Make sure that the option in the Type column of the LAP TRIGGER SOUR...

Page 77: ...GER User Manual Rev AD sales get athena eu www getdata it ENGLISH Press the field in the Track column and select a track from the list then confirm Press Set Conf to send the new configuration to the...

Page 78: ...wer supply and analogue frequency input negative 6 SL1TOEXT Reserved 7 EXTTOSL1 Reserved 8 IC1 Frequency input 0 12V 9 BEACON Reserved MAIN connector Front view The wires exit from the rear EXP connec...

Page 79: ...na eu www getdata it ENGLISH 3 USB CONNECTOR USB Connector Pinout PIN SIGNAL NAME DESCRIPTION 1 USB USB signal 5V 2 USB N USB signal Data N 3 USB P USB signal Data P 4 ID USB signal ID 5 USB USB GND U...

Page 80: ...SL1 Data Logger 1 MAIN POWER IC WIRING CODE GL 0178 AA MAIN POWER connector pinout CONNECTOR CABLE PIN DESCRIPTION IC1 BCN 1 Power supply positive 2 Input signal 3 Ground GND SEN INTERFACE CABLE 1 Pow...

Page 81: ...Logger EXP Connector Pinout CONNECTOR PIN DESCRIPTION AN1 AN2 AN3 1 5 VDC VREF 2 Input signal 3 Ground GND SEN CAN EXP 1 CAN Port EXP CANL signal 2 CAN Port EXP CANH signal 3 NC not connected 4 NC no...

Page 82: ...r the GP1 RX1 ECUs family or LC1 EVO lambda module data via CAN Bus GPA CONNECTOR input for the GPA SWITCH module MAIN SL1 CONNECTOR input for the SL1 Data Logger connection MAIN connector PWR CONNECT...

Page 83: ...na eu www getdata it ENGLISH ANNEX 4 SL1 CONNECTION DIAGRAM The following chapters show some connection examples 1 RX1 GP1 ECUS SL1 BATTERY LESS CONFIGURATION NOTE USING OPT ALL THE CONNECTED DEVICES...

Page 84: ...ual Rev AD sales get athena eu www getdata it ENGLISH 2 APPLICATION OFFROAD CAN BUS EXT SENSORS RX1 GP1 ECUS SL1 CONF BATTERY LESS NOTE USING OPT 1 ALL THE CONNECTED DEVICES WILL BE POWERED WITHOUT HA...

Page 85: ...85 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH 3 APPLICATION ROAD CAN BUS EXT SENSORS SL1 ECULMB ECU E G YZF R25 R3 D30 DASH...

Page 86: ...86 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH 4 APPLICATION ROAD CAN BUS EXT SENSORS SL1 ECULMB ECU E G YZF R25 R3 D30 DASH...

Page 87: ...athena eu www getdata it ENGLISH 5 ANALOGUE CONNECTION LC1 EVO NOTE USING OPT 1 ALL THE CONNECTED DEVICES WILL BE POWERED WITHOUT HAVING TO TURN ON THE ENGINE OPT 2 IS REQUIRED ONLY IF FREQUENCY SIGNA...

Page 88: ...88 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH 6 SENSORS SL1 FOR TYPE...

Page 89: ...RI IC Gas valve position sen sor TPS cod GS POS 0001 Brake pressure sensor Motor temperature sensor NTC cod DS40050000 Manual log switch cod GE DVC S2 0001 Lambda LC1EVO cod GK LC1EVO 0001 Exhaust tem...

Page 90: ...90 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH NOTES...

Page 91: ...91 SL1 DATA LOGGER User Manual Rev AD sales get athena eu www getdata it ENGLISH NOTES...

Page 92: ...sales get athena eu www getdata it...

Reviews: