DYN,ALU1 ALU2, ALU3, ALU4, ALU5, ST Balancing modes
1.
Select the appropriate balancing method for your rim by pressing the button.
.
2.
Enter the A,B,D values (except in ALUS mode).:
-
* Setting the "a" value: Move the gauge to the first measuring point (e.g. as shown in Fig.1), hold
the gauge (for approx. 4 seconds) in this position, after confirmation return the gauge to the 0
position. (The measured value is automatically shown in the display).
-
* Setting the "b" value: Read off the diameter indicated on the wheel or use the width gauge (as
shown in Fig.2), then enter the value using the
or
buttons.
-
* Setting the "d" value: This value is automatically measured when the "a" value is taken over.
fig.1
fig.2
After the parameters a/b/d have been entered, close the wheel guard or press the button
to
start the balancing process. As soon as the balancing process is finished, the internal and external
unbalance is shown in the display (+-5g), by pressing the button
the exact unbalance (+-1g)