2.4
Location
The machine should be kept away from flammable and explosive materials, as well as from sunlight and
intense light. The machine should be placed in a well-ventilated location.
The machine must be set up on sufficiently firm ground, if necessary, according to the minimum
requirements of the information given in the foundation plan.
In addition to the ground conditions, the guidelines and instructions of the accident prevention regulations
as well as the workplace regulations must be observed when selecting an installation site.
When assembling
on floor coverings, check their load-bearing capacity. A construction expert should be
consulted for inspection when mounting on floor coverings.
The machine should only be mounted and used within closed rooms. It has no corresponding safety
features (e.g. IP protection, galvanised design, etc.).
Temperature
4-40 °C
Sea level
< 1500 m
Humidity
50% at 40 °C – 90% at 20 °C
Drawing
Safety range
Min. 1 m
Permissible operating temperatures:
10-40 °C
Maximum permitted humidity:
≤80% at 30 °C
Altitude above sea level:
≤2000m
Power connection & grounding cable (see technical data) must be installed in the form of a plug device
(socket and plug) or a fixed connection.
Necessary supply line
See technical data