Read and understand this manual prior to connection and operation of the device. Keep the User

Manual with the device for future reference. 
The manufacturer shall not be held responsible for any errors, damage or defects caused by
improper selection of suitable devices or cables, errors in installation of equipment or any misuse

due to failure to understand the document content. 
Unauthorised repairs and modifications of the device are not allowed. The manufacturer shall
discard any responsibility for consequences of such actions. 
Exposure of the device to the impact of excessive mechanical, electric or environmental factors

may lead to damage of the device. 
Operation of damaged or incomplete devices in not allowed. 
Engineering   of   a   gas   safety   system   for   any   specific   facilities   to   be   safeguarded   may   need
consideration of other requirements during the entire lifetime of the product. 
Use of unauthorized spare parts different from the ones listed in Table 9 is strictly forbidden.

How to use this manual?

The following symbols of optical indicators status are used throughout the document:

Symbol

Interpretation

Optical indicator on
Optical indicator flashing
Optical indicator off
Optical indicator status not determined (depends on other factors)

Table 1: Optical indicators status notation

Important fragments of the text are highlighted in the following way: 

Pay extreme attention to information provided in such framed boxes.

This   User   Manual   consists   of   a   main   text   and   attached   appendices.   The   appendices   are
independent   documents   and   can   be   used   separately   from   this   Manual.   Page   numbering   of

appendices starts  anew  with  no  relationship  to pare numbering  of  the  main  document  and
appendices may have their own tables of contents. In the right bottom corner of each page you

can find the name (symbol) of any document included into the User Manual package with its
revision (issue) number. 

s. 3|15

User Manual: POD-067-ENG R01

Summary of Contents for Control V

Page 1: ...POD 067 ENG R01 User Manual Valve Controller Control V Product code PW 121 X...

Page 2: ...ring Detection and Reduction of gas hazards We invite you to familiarize yourself with our offer on www atestgaz pl Atest Gaz A M Pachole sp j ul Spokojna 3 44 109 Gliwice Poland tel 48 32 238 87 94 f...

Page 3: ...nts during the entire lifetime of the product Use of unauthorized spare parts different from the ones listed in Table 9 is strictly forbidden How to use this manual The following symbols of optical in...

Page 4: ...ce status 8 Table 4 Meaning of LED indicators in the battery status 8 Table 5 Meaning of LED indicators in the valve status 9 Table 6 Description of TEST button 9 Table 7 Selection of cables for conne...

Page 5: ...f the controller is subjected to continuous monitoring of its operability and its key parameters where such items as continuity of the line for valve control its resistance charging status of the embe...

Page 6: ...roper way Before painting the floors make sure the device is secured 3 Description of the construction Product code Dimensions mm A B C D E PW 121 L X 125 110 125 110 75 PW 121 H X 175 160 125 110 100...

Page 7: ...2 Electric interface description 4 1 1 Power supply port for a valve to be controlled The output port designed to supply a shutoff valve The port is monitored resistance of the output line is continuo...

Page 8: ...igital communication with other devices of the Teta series PLN Power Line Networking 5 User interface Figure 4 Front panel 5 1 Device status Indicator Status colour Information green Regular operation...

Page 9: ...ection 7 5 1 Indicator Status colour Information No need to test the valve green Slow blinking of the LED indicator test of the valve is needed see details in Section 7 5 1 green Test of the valve is...

Page 10: ...ll with cable glands downwards where the mounting position is shown in 2 The location of the device should be easily accessible to operating personnel but access of unauthorized persons should be rest...

Page 11: ...f cable cores mm2 Cross section of a cable parallel connection of cores mm2 Maximum length of the cable for valves with power 72 W m Maximum length of the cable for valves with power 36 W m 1 5 2x1 0...

Page 12: ...ted to the controller On the contrary moving the switch to the OFF position makes the controller to close the shutoff valve connected to the valve port when the contacts of the DI port are shorted see...

Page 13: ...e order 7 5 3 Maintenance Except cleaning the external part of the enclosure the device does not require any maintenance The external part of the enclosure should be cleaned by means of a soft cloth m...

Page 14: ...ial free contact Inactive for resistance below 10 Active for resistance above 3300 Minimum duration of the switchover pulse 1s Digital communication parameters Teta BUS port Communication protocol Tet...

Page 15: ...ry 12 V 5 Ah 1 year MW Power MW 5 12 Table 9 List of consumables 10 Product marking Control V Valve Controller PW 121 Valve type L Coil resistance 4 power consumption 36 W H Coil resistance 2 power co...

Page 16: ...certain voltage limits EN 60335 1 2012 in relation to directive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment EN 50581 2012 other EN 6...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: