10
9
No.
Parameters
Function description
1
2
3
Charger IP
Server URL2
Server URL1
Server address setting, used to set domain or IP
address of back-office server.
IP setting of the charging equipment
Address of backup server. This parameter is not
available now, reserved for future use.
4
Subnet mask
Subnet mask setting
5
Gateway
Gateway setting
6
DNS
DNS server address
7
MAC Addr
MAC address
8
Server IP
Server IP address
9
Server port
Server port number
10
WIFI SSID
WIFI SSID setting, to set the name of the wireless
network to which the charging equipment is to
be connected. A reserved function for future use
11
WIFI Key
WiFi password setting. A reserved function for
future use
12
Authentication Key OCPP login authentication setting
No.
Parameters
Function description
1
2
3
4
5
6
7
8
9
DC output overvoltage value
DC output overcurrent value
AC input overvoltage value
AC input undervoltage value
AC input overcurrent value
DC output limit power
Charger over temperature value
Charger derate temperature value
Insulation Resistance
Over voltage limit setting of DC
output
Over current limit setting of DC
output
Over voltage limit setting of AC
input
Under voltage limit setting of AC
input
Over current limit setting of AC
input
Power limitation setting of DC
output
Over temperature limit setting of
charging connector
Charging connector’s temperature
at which the charging equipment
starts decreasing output power
The min value of insulation
resistance
If the charger is connected to the server through the network cable, the Charger
IP, Subnet mask and Gateway need to be set. Through WiFi, you need to set WiFi
SSID and WiFi Key. With 4G, you can connect to the server by installing a SIM
card.
4.3 Protection parameters
The protection-related parameters, such as voltage, current, temperature, power,
etc.