7.2 Warranty

Warranty period

The warranty period of this product is 1 year. If the contract stipulates otherwise, 
the contract shall prevail.
For  warranty  cases  during  the  warranty  period,  the  customer  should  present  the 
invoice  of  the  purchase  of  the  product  to  the  service  personnel  of ATESS  Power 
Technology.  At  the  same  time,  the  nameplate  on  the  product  should  be  clearly 
visible, otherwise the warranty claim might not be accepted.

Warranty condition

ATESS  Power  Technology  Co.,  Ltd.  will  repair  or  replace  the  product  free  of 
charge during the warranty period. The defective machine after replacement shall 
be owned by ATESS Power Technology, and the customer shall reserve a certain 
amount of time for ATESS Power Technology to repair the faulty machine.

Liability exemption

ATESS Power Technology reserves the right not to accept the warranty claim if the 
conditions below happen,
1.No ATESS logo on the product;
2.Warranty period has expired;
3. Fault or damage caused by incorrect installation, by installing the device in a not 
allowed  environment,  by  improper  storage  or  usage,  etc.(e.g.  too  high  or  too  low 
temperature,  moisture  or  too  try  environment,  high  altitude  or  unstable 
voltage/current, etc.)
4.Failure  or  damage  caused  by  the  installation,  repair,  modification  or 
disassembly byunauthorized service personnel;
5.Failure  or  damage  caused  by  using ATESS  Power Technology’s  genuine  spare 
parts;
6.Damage  or  damage  caused  by  accident  or  human  cause  (operational  error, 
scratching, handling, bumping, access to inappropriate voltage, etc.), or transport 
damage;
7.Failure  or  damage  caused  by  force  majeure  such  as  natural  disasters  (such  as 
earthquakes, lightning strikes, fires, etc.);
8.Other failures or damages that are not caused by quality problem of the product 
or its components.

Statement of liability

The copyright of this manual belongs to Shenzhen ATESS Power Technology Co., 
Ltd.  Any  organization  or  individual  may  not  extract  or  copy  part  or  all  of  the 
contents  of  this  manual  without  any  written  permission  from  ATESS  Power 
Technology,  and  may  not  be  reproduced  and  spread  in  any  form  (including 
materials and publications). ATESS Power Technology Co., Ltd. has the final right 
to interpret this manual. This manual is subject to change without prior notice.
For more information, please access www.atesspower.com.

7.3 Contact

Company Name:Shenzhen Atess Power Technology Co.,Ltd

Address:

 3rd floor, building 9, Henglong industrial park, the fourth industrial zone of Shuitian 

community, Baoan district, Shenzhen, China

Website: www.atesspower.com

Service line: +8675529988492

E-mail: [email protected]

 

20

Summary of Contents for EVD-60D

Page 1: ...t user manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E i...

Page 2: ...ly for electric vehicles which has a friendly man machine interface and integrates corresponding functions of control billing communication and security protection The charging equipment uses OCPP 1 6...

Page 3: ...stem Parameters 4 2 Network parameters 4 3 Protection parameters V Operation instruction and LCD introduction 5 1 Charging mode and operation 5 2 LCD interface introduction 5 3 Appendix Fault code VI...

Page 4: ...erson can operate the breaker in the surge protection circuit and replace the lightning protection module The red circle in the figure is the lightning protection status indicator When the indication...

Page 5: ...area to avoid flooding water 2 The foundation pile is to be made of reinforced concrete which requires for a minimum allowable bearing pressure of 1000kg squire meters for the base 3 Construct main gr...

Page 6: ...and phase sequence The earth cable shall be connected to the grounding bar of the charger Wiring illustration is shown in elow Please notice For safety the charger must be grounded securely Connect th...

Page 7: ...charge mode payment is not needed 2 is APP or RFID mode No Parameters Function description 8 9 10 Time set Language set Meter address DC meter s modbus address already preset in factory it is not allo...

Page 8: ...rvoltage value DC output overcurrent value AC input overvoltage value AC input undervoltage value AC input overcurrent value DC output limit power Charger over temperature value Charger derate tempera...

Page 9: ...and payment provided that the back office server supports such function 4 5 2 3 1 APP RFID mode operation process flow Plug Charge Charging will start automatically after EV plugged in If you want to...

Page 10: ...when entering each parameter setting page Password window Before entering numeric please first press the text display field to move the cursor there then you can type in the 4 digit password A wrong p...

Page 11: ...e disconnection fault AC Contactor sticking fault AC Input Overvoltage AC Input Undervoltage BMS communication fault VI Specification Model EVD 60D Dimension mm 1883 600 743 W H D Weight kg 240KG Disp...

Page 12: ...C output Over temperature protection Short circuit protection Emergency stop protection Lightning protection Leakage protection 20 50 Ip54 95 2000m derate for higher than 2000m Forced air cooling Ethe...

Page 13: ...etc 4 Failure or damage caused by the installation repair modification or disassembly byunauthorized service personnel 5 Failure or damage caused by using ATESS Power Technology s genuine spare parts...

Reviews: