5.3 Appendix: Fault code
No.
Fault description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Emergency stop is pressed!
RFID communication fault!
Lightning protection fault!
Power module communication fault!
Over temperature fault!
DC output overvoltage fault!
Meter communication fault!
DC output overcurrent fault!
Waiting for BMS communication timeout!
Insulation detection timeout!
Insulation detection fault!
DC+ Contactor sticking fault!
DC- Contactor sticking fault!
Battery voltage reverse fault!
Plug head connection over temperature fault!
Plug line disconnection fault!
AC Contactor sticking fault!
AC Input Overvoltage!
AC Input Undervoltage!
BMS communication fault!
VI. Specification
Model
EVD-60D
Dimension(mm)
1883*600*743(W*H*D)
Weight(kg)
240KG
Display
LCD
Casing material
AC input
Grid connection
Current
Voltage
Stainless steel&acrylic sheet
400V, 3 phase 5 wires
AC 260~530V
86.6A
50HZ
Frequency
Voltage
Current-stabilizing accuracy
Power factor
Efficiency
≥
0.95 @20
%~
50
%
of full load output power
≤±
1
% (
at 20
%~
100
%
of rated power)
≥
0.98 @50
%~
100
%
of full load output power
≥
0.99 @100
%
full load output power, rated
input voltage and frequency
≥
95.2
%
,
@
750V, 50
%~
100
%
of rated current
and rated input voltage
DC output
Plug type
CHAdeMO
DC150
~
500V
0-125A
CCS
DC150~750V
0-125A
Current
Voltage-stabilizing accuracy
<±
0
.
5
%