ATESS EVD-60D User Manual Download Page 12

IP degreel

Working environment

Relative humidity

Altitude

Cooling method

Remote monitoring

Payment

Standby power

Standards

Mounting

Metering accuracy

Certificate

Protection features

Low and high trip limit of AC 

input voltage

Over voltage trip limit of DC 

output

Over temperature protection

Short circuit protection

Emergency stop protection

Lightning protection

Leakage protection

-20

~+50

Ip54

<95

2000m, derate for higher than 2000m

Forced air cooling

Ethernet/WIFI/4G/485/232

RFID/APP

25W

IEC-62196-2;EN61851

Ground

CE

0.5

Adjustable within 260~457V AC

Adjustable within 260V~778V DC or 260V~500V

Yes

Derate since 50

; Stop at 75

Yes

Type A

Type II

VII. Appendix

7.1 Electric diagram

F

ig

7

-1

, M

a

in c
ir

c

u

it d
ia

g

ra

m

Summary of Contents for EVD-60D

Page 1: ...t user manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E i...

Page 2: ...ly for electric vehicles which has a friendly man machine interface and integrates corresponding functions of control billing communication and security protection The charging equipment uses OCPP 1 6...

Page 3: ...stem Parameters 4 2 Network parameters 4 3 Protection parameters V Operation instruction and LCD introduction 5 1 Charging mode and operation 5 2 LCD interface introduction 5 3 Appendix Fault code VI...

Page 4: ...erson can operate the breaker in the surge protection circuit and replace the lightning protection module The red circle in the figure is the lightning protection status indicator When the indication...

Page 5: ...area to avoid flooding water 2 The foundation pile is to be made of reinforced concrete which requires for a minimum allowable bearing pressure of 1000kg squire meters for the base 3 Construct main gr...

Page 6: ...and phase sequence The earth cable shall be connected to the grounding bar of the charger Wiring illustration is shown in elow Please notice For safety the charger must be grounded securely Connect th...

Page 7: ...charge mode payment is not needed 2 is APP or RFID mode No Parameters Function description 8 9 10 Time set Language set Meter address DC meter s modbus address already preset in factory it is not allo...

Page 8: ...rvoltage value DC output overcurrent value AC input overvoltage value AC input undervoltage value AC input overcurrent value DC output limit power Charger over temperature value Charger derate tempera...

Page 9: ...and payment provided that the back office server supports such function 4 5 2 3 1 APP RFID mode operation process flow Plug Charge Charging will start automatically after EV plugged in If you want to...

Page 10: ...when entering each parameter setting page Password window Before entering numeric please first press the text display field to move the cursor there then you can type in the 4 digit password A wrong p...

Page 11: ...e disconnection fault AC Contactor sticking fault AC Input Overvoltage AC Input Undervoltage BMS communication fault VI Specification Model EVD 60D Dimension mm 1883 600 743 W H D Weight kg 240KG Disp...

Page 12: ...C output Over temperature protection Short circuit protection Emergency stop protection Lightning protection Leakage protection 20 50 Ip54 95 2000m derate for higher than 2000m Forced air cooling Ethe...

Page 13: ...etc 4 Failure or damage caused by the installation repair modification or disassembly byunauthorized service personnel 5 Failure or damage caused by using ATESS Power Technology s genuine spare parts...

Reviews: