Serial Console Server User Manual
102
Console Server will not be found. An explanation of the fields is given in the
table below:
Note:
1. Valid entries for all of the Service Ports are from 1–65535.
2. Service ports cannot have the same value. You must set a different
value for each one.
3. If there is no firewall (on an intranet, for example), it doesn’t matter
what these numbers are set to, since they have no effect.
Network Configuration
Redundant NIC*
The SN0108CO / SN0116CO / SN0132CO / SN0148CO are designed
with two network interfaces. If
Enable
Redundant NIC
is enabled (the
default), both interfaces make use of the IP address of network adapter
eth0
.
Under this configuration, the second interface is usually inactive. If there
is a network failure on the first interface, the Serial Console Server
automatically switches to the second interface.
Redundant NIC Enabled – Single IP Address for Both Interfaces
To enable the Redundant NIC function, do the following:
1. Click to put a check in the
Enable Redundant NIC
checkbox.
2.
eth0
is selected in the network adapter listbox, and the listbox is
disabled – you cannot configure
eth1
.
3. Configure the IP and DNS server addresses for
eth0
(see the
sections below).
Redundant NIC Not Enabled – Two IP Addresses
If you choose not to enable the Redundant NIC function, the two NICs
can be configured with separate interfaces. Users can log into the
SN0108CO / SN0116CO / SN0132CO / SN0148CO with either IP
Field
Explanation
HTTP
The port number for a browser login. The default is 80.
HTTPS
The port number for a secure browser login. The default is 443.
SSH Port
The port for SSH access. The default is 22.
Telnet Port
The port for Telnet access. The default is 23.
Base Socket
The port used to listen for and accept a TCP connection
Summary of Contents for SN0108CO
Page 1: ...ATEN Altusen SN0100CO SN0100COD SN9100CO Series Serial Console Server User Manual ...
Page 16: ...Serial Console Server User Manual xvi This Page Intentionally Left Blank ...
Page 36: ...Serial Console Server User Manual 20 This Page Intentionally Left Blank ...
Page 47: ...Chapter 2 Hardware Setup 31 SN9108CO SN9116CO Installation Diagram ...
Page 48: ...Serial Console Server User Manual 32 This Page Intentionally Left Blank ...
Page 131: ...Chapter 8 Device Management 115 Console Port Settings SN0108CO SN0116CO SN0132CO SN0148CO ...
Page 141: ...Chapter 8 Device Management 125 Association The Association tab is currently reserved ...
Page 144: ...Serial Console Server User Manual 128 This Page Intentionally Left Blank ...
Page 156: ...Serial Console Server User Manual 140 This Page Intentionally Left Blank ...