BMC Not Responding
Problem:
The BMC does not respond. The host system can’t be powered off, powered on, or
power cycled. Host system health information cannot be obtained.
Explanation:
1. Use server’s onboard BMC to access health information was not enabled in IPMI
configuration.
2. The BMC I2C address isn’t set to 0X20. 0x20 is the correct address for almost all
BMCs. If it is not, the BMC or motherboard provider must supply the correct one.
Solution:
1. Make sure Use server’s onboard BMC to access health information is enabled in
IPMI configuration.
2. Make sure the BMC I2C address is set to 0X20.
Note: Many BMCs feature a reset button that can be used to reset the BMC only.
That button can be used to reset the BMC. If using a BMC without a BMC
reset button, the system must be powered off and the power cable(s)
unplugged. Some BMCs will run on system standby power, and stay on even
though the system is in an off state.