4.4 How to check parameter setting & measured values of current status
In standby or running status press or to find parameter 0-A and measured values of current status.
Parameter
Definition
Range
Default
Remark
0
1
2
3
4
5
6
7
8
9
Desired water temperature in cooling mode
Desired water temperature in heating mode
Defrosting cycle
Evaporator temperature set point for stopping defrosting
Maximum duration for defrosting
Number of compressors in the system
Restart after power failure
Type: Cooling only 0/
Heating &cooling 1/
Heating & c Auxiliary heating 2/
Heating only 3/
Different working mode of water pump:
water pump keeps working always 0/
water pump works in accordance
with heat pump 1 /
8
~
28
℃
15
~
40
℃
30
~
90Min
-30
~
0
℃
2
~
30
℃
1
~
15Min
1
~
2
0
~
1
0
~
3
0
~
1
12
℃
40
℃
45Min
-7
℃
13
℃
8Min
1
(
Yes
)
1
0
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
A
B
C
D
E
F
Desired
water temperature in auto mode
Actual inlet water temp.
Actual outlet water temp.
Coil temp. in system 1
Ambient temp.
8
~
40
℃
30
℃
Ajusted
by Technicians
-9
~
90
℃
-9
~
90
℃
-9
~
90
℃
-9
~
90
℃
Measured Value
Measured Value
Measured Value
Measured Value
Coil temp. in system 2
-9
~
90
℃
Measured Value
Evaporator temperature set point for starting defrosting
1
18
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP
MODE
1
0
HEAT
COOL
AUTO
Parameter 1
MODE
1
0
HEAT
COOL
AUTO
Current status
measured value