The heat pump's running setting parameter can be set on the wire controller.
Please set the parameter according to the below table:
15
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP
Parameter
Definition
Range
Default
Remark
00
01
02
03
04
05
06
07
08
10
Desired
water temperature in cooling mode
Desired water temperature in heating mode
Defrosting cycle
Evaporator temperature set point for stopping
defrosting
Maximum duration for defrosting
Number
of
compressors
in
the
system
Restart after power failure
Type: Cooling only 0/
Heating &cooling 1/
Heating & c Auxiliary heating 2/
Heating only 3/
Desire
water
temperature
in
auto
mode
8
~
28
℃
15
~
40
℃
30
~
90Min
-30
~
0
℃
2
~
30
℃
1
~
15Min
1
~
2
0
~
1
0
~
3
8
~
40
℃
12
℃
40
℃
45Min
-
7
℃
“
-
”
is not displayed
13
℃
8Min
1
(
Yes
)
1
30
℃
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Ajusted
by Technicians
Evaporator temperature set point for starting defrosting
1
0
~
1
0
Ajusted
by Technicians
Different working mode of water pump:
water pump keeps working always 0/
water pump works in accordance
with heat pump 1 /
09
Important:
Icon
“-”
which
stands
for below
“
0
”
degree
CAN
NOT
be
displayed here. Value
“
1-30
”
stands
“- 1℃ ”
to
“
-30
℃ ”
.Default
setting
“
7
℃ ”
actually
stands for
“
-7
℃ ”.
Remarks
: Standby status means the unit is connected with electricity but not running .Parameter 00-10
can
ONLY
be changed under standby status!
When heat pump is in running status, press and to check the current status of the unit. You can check
water-in / water-out temperature, condenser temperature and ambient temperature. Please note no press
on the controller for 5 seconds, controller will return to main interface, which displays water-in and
water-out temperature.
When heat pump is in standby status, controller will display only ambient temperature.
3.4 How to know current status