When all connections have been made and checked, you should follow these steps:
1. Turn on the filter pump. Check for leaks and verify flow to and from the pool.
2. Turn on the electrical power supply to the unit, then press the ON/ OFF key on the electronic control
panel. The unit should start when the time delay period has lapsed .
3. When
the
unit
has
been
running
for
a
couple of minutes, check if
the
air
leaving
the unit is cooler.
4. Check the performance of the flow switch as follows: with the unit running, turn the filter pump off.
The unit should also switch off automatically. If not, the flow switch must be readjusted.
5. All the unit and filter pump to run 24 hours a day until the desired pool water temperature is reached.
When the set temperature is reached, the unit switches itself off. The unit will now automatically
restart (as long as your filter pump is running) when the temperature of the pool water experiences a
drop of more than 1
℃
below
the
set
temperature
.
Note- In order for the unit to heat the pool (or spa), the filter pump must be running so that
the
water
can circulate
through
the heat
pump. Without
this
circulation, the heat pump will not start.
2.9
First time start-up
2.10
Condensation
When the swimming pool water is being heated by the heat pump, the incoming air is cooled down quite
a bit, which can cause condensation on the fins of the evaporator. Condensed volumes can attain severa
l litres per hour underhigh atmospheric humidity. Sometimes, this is wrongfully interpreted as a water leak.
Model
WBR-45.0H-A-S
WBR-50.0H-A-S
WBR-90.0H-A-S
WBR-135.0H-A-S
WBR-158.0H-A-S
WBR-9.5H-B1
WBR-12.5H-B1
WBR-14.0H-B1
WBR-17.0H-B1
WBR-14.0H-B1-S
WBR-17.0H-B1-S
WBR-21.0H-B1-S
WBR-26.0H-B1-S
WBR-35.0H-A-S
Voltage(volt)
Fuse(A) Nominal current(A)
2
Cable diameter(mm )
(for max.length of 15 meters
3x
415
3x
415
3x
415
3x
415
3x
415
220-240
220-240
220-240
220-240
3x
415
3x
415
3x
415
3x
415
3x
415
20
25
32
60
80
80
16
20
25
25
10
16
16
16
12.7
16.4
18.2
32.9
40.6
47.6
9.1
12.0
13.4
16.3
4.9
5.9
7.2
8.9
4x2.5+2.5
4x4.0+4.0
4x4.0+4.0
4x10.0+10.0
3x16.0+2x10.0
3x16.0+2x10.0
2x2.5+2.5
2x2.5+2.5
2x4.0+4.0
2x4.0+4.0
4x2.5+2.5
4x2.5+2.5
4x2.5+2.5
4x2.5+2.5
Time delay
—
the unit is equipped with a
built
-
in 3
-
minute start delay included
to
protect
electrical
components and contacts
.
After
this
time
delay, the unit
will
automatically
be
restarted. Even a
brief
interruption of the power supply will
activate
the start delay and
prevent the unit
from starting
immediately. Additional interruptions of the power supply during the delay period will have no effect
on the
3
-
minute
countdown
.
Water flow switch
—
the unit is equipped with a flow switch that
is
switched on when enough water has
flowed
through
the unit
and
that
is
switched
off
when
the
water
flow
becomes
too
low.
(
e
.
g.
when the filter pump is switched
off
).
Depending on the starting temperature of the pool water and the air temperature, it can take several days
for the water to reach the desired temperature. Covering the pool can drastically reduced this period.