LPX-1000 Scanner System
User Manual
Section 2
Copyright © 2008-2012 ATCO. All Rights Reserved.
850-004134
Page 6
Revision A.0
Latch the link by rotating the Latching Lever back as shown
right. The scanner requires a minimal amount of force to
sufficiently hold the scanner in place.
CAUTION:
It should only take a few pounds of force exerted
on the Latching Lever. Be careful not to use too much force
when clamping the scanner chain. Excessive force can damage
the components of the system.
Adjusting the Y-Axis
The Y-Axis can be adjusted to support
various configurations. The height of the
Y-Axis can be changed by rotating the arm
as shown right. Using a 3/16" allen
wrench, loosen the two fasteners on the
mounting arm (shown right) to adjust the
arm.
The fasteners used are listed below in case
replacements are needed. They are listed
by number according to the callout in the
figure to the right.
1)
1/4-28 x 1 ½" Socket Hd Screws
2)
6-32 x ½” Socket Hd Screws
3)
6-32 x 3/8" Socket Hd Screws
CAUTION
Use Minimal Force
to Latch
1
2
3
Loosen to Raise/Lower Axis (2)
Use 3/16" Allen Wrench