LPX-1000 Scanner System
User Manual
Section 2
Copyright © 2008-2012 ATCO. All Rights Reserved.
850-004134
Page 3
Revision A.0
The MCU-P500 motor control unit is battery operated. A 110VAC power supply / charger is provided which can be
used to power the unit. Refer to the MCU-500P Manual for more details.
Clamping Chain
The Clamping Chain can be used to hold the scanner
in place for piping or similar applications that require
it. The chain assembly is made up of a series of links
and a latch hook. Adjust the number of links
according to the diameter of the pipe being scanned.
Combinations of links will accommodate virtually any
diameter of pipe.
Use the table in Appendix C to determine the
combination of links required for the diameter piping
you are working with.
CHARGE
X-SPEED
Y-SPEED
Y-
A
XI
S
X-
AX
IS
RE
M
OTE
+
+
MCU-P500
1
2
3
4
5
6
7
8
9
0
ESC
SPC
BSPC
ENT
Scanner Control
Cable
Recepticles
Remote Contro
Recepticle
Keypad
Charger
Recepticle
Power
Switch
X & Y Speed
Controls
Emergency
Stop
Display
Battery Cover
Scanner
Latching Link
Links
Rubber Tires