APPENDIX C: S-REGISTERS
DEFINITY Communications System
7400B Plus Data Module
Page C-12
User´s Guide
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
Register:
S18
Description:
The value in this S-register establishes the duration of diagnostic
tests initiated by the
&T
command.
Range of
Values:
Value may be 000 through 255 seconds. The factory-default
value is 0.
Storable:
yes
Comments:
Any locally initialized test in progress is automatically
terminated when the time specified in S-register 18 has elapsed.
If S-register 18 is set to 0, a test initiated by the
&T
command
must be terminated manually. Issuing the
&T0
command
terminates any locally initiated test immediately, regardless of
the value in S-register 18.
See Also:
Chapter 3, "Configuration and Operation;" Appendix A, "AT
Command Set."
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
Register:
S19
— not used
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
Register:
S20
— not used
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb