background image

Astria.US.com

127051-01D

3

SAFETY

 Continued

 WARNING: CONTINUED OVERFIRING CAN PER-

MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. 

SOME EXAMPLES OF CONDITIONS THAT COULD 

CAUSE OVERFIRING ARE:

•  BURNING QUANTITIES OF SCRAP LUMBER, PINE 

BRANCHES,  PAPER  OR  CARDBOARD  BOXES 

WHICH EXCEED THE VOLUME OF THE NORMAL 

LOG FIRE.

•  BURNING TRASH, CHEMICALS OR CHEMICALLY 

TREATED COMBUSTIBLES.

Disposal of Ashes 
Ashes should be placed in a metal container with a 

tight-fitting lid. The closed container of ashes should 

be placed on a noncombustible floor or on the ground, 

well away from all combustible materials, pending 

final disposal. If the ashes are disposed of by burial 

in soil or otherwise locally dispersed, they should be 

retained in the closed container until all cinders have 

thoroughly cooled.

WHEN USING THE DECORATIVE APPLIANCE, THE 

FIREPLACE DAMPER MUST BE SET IN THE FULLY 

OPEN POSITION.

Never use gasoline, gasoline-type lantern fuel, kero-

sene, charcoal lighter fluid, or similar liquids to start 

or ’freshen up’ a fire in this fireplace. Keep all such 

liquids well away from the fireplace while it is in use.

Use SOLID WOOD only for fuel. It is best to use dry 

and well seasoned hardwood. Softwoods tend to burn 

very quickly. DO NOT use treated wood, charcoal, coal, 

trash, driftwood or woods that have been dipped in tar, 

pitch, pine tar, creosote, etc. Wood products made 

with synthetic binders, such as plywood, produce ab-

normally high temperatures and sputtering, smoking 

fires.  When burning artificial logs, please read and 

follow the instructions provided by the manufacturer.

Never burn treated construction lumber or scraps. 

These woods burn excessively hot and may contain 

chemicals used to treat insects and fungus. When 

burned, these chemicals can pose a significant hazard.

 WARNING: BURNING IMPROPER FUEL (I.E. 

CHARCOAL) CAN RESULT IN CARBON MONOXIDE 

POISONING, WHICH MAY LEAD TO DEATH! 
Carbon Monoxide Poisoning – Early signs of carbon 

monoxide poisoning resemble the flu with headaches, 

dizziness, or nausea. If you have these signs, get 

fresh air at once!  Have the appliance inspected by a 

qualified service technician.  Some people are more 

affected by carbon monoxide than others.  These 

include pregnant women, people with heart or lung 

disease or anemia, those under the influence of al

-

cohol, and those at high altitudes.

Ventilation Requirements - Provide adequate air for 

combustion. The fresh air requirements of this ap-

pliance must be met within the space where it will 

be installed.

Smoke Detectors - Since there are always several 

potential sources of fire in any home, we recommend 

installing smoke detectors. If possible, install the 

smoke detector in a hallway adjacent to the room (to 

reduce the possibility of occasional false activation 

from the heat produced by the appliance).  If your local 

code requires a smoke detector be installed within the 

same room, you must follow the requirements of your 

local code. Check with your local building department 

for requirements in your area.

Creosote – Formation and Need for Removal 

When wood is burned slowly, it produces tar and other 

organic vapors, which combine with expelled moisture 

to form creosote. The creosote vapors condense in 

the  relatively  cool  chimney  flue  of  a  slow-burning 

fire. As a result, creosote residue accumulates on 

the flue lining. When ignited this creosote makes an 

extremely hot fire. 

The chimney shall be inspected at least twice a 

year during the heating season to determine when a 

creosote buildup has occurred. When creosote has ac-

cumulated (1/8" [3 mm] or more) it shall be removed 

to reduce the risk of a chimney fire.

Summary of Contents for Tuscan42P2

Page 1: ...og heater see Accessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de déterminer la nécessité d obtenir un ...

Page 2: ...dification of the fireplace components doors air inlet system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all...

Page 3: ...to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service te...

Page 4: ...USTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE PERPENDICULAR NOT LESS THAN 12 TO SIDEWALL 41 48 42 8 39 12 48 36 24 8 1 8 10 5 8 12 5 8 10 5 8 6 3 4 14 1 4 2...

Page 5: ...mum Maximum Chimney Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections required for outdoor installation Figure 1 Framing Dimensions Figure 2 Corner Installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 1 and 2 Note Whe...

Page 6: ...pan with provision for drainage be installed under the fireplace within the fireplace enclosure see Accessories page 19 HEARTH EXTENSION A hearth extension projecting a minimum of 20 in front of and a minimum of 12 beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace Fab ricate a hearth extension using a material which meets the followin...

Page 7: ... 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in lineal gain chart see Figure 6 Lineal gain is actual measurable length of a part after two or more parts are connected Figure 6 Lineal Gain Hemmed End 8 Stainless Inner Pipe 1...

Page 8: ... page 9 The height of a vertical chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSET 30E 12DMO 8DMR To clear overhead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be used...

Page 9: ... 24 1 2 50 3 4 1 1 2 27 1 2 56 1 1 1 1 30 1 4 61 1 1 2 31 62 1 2 1 1 1 32 1 2 65 1 1 2 1 35 1 2 70 1 4 1 1 1 2 36 1 4 71 1 2 1 1 1 1 37 72 3 4 1 1 1 38 1 2 75 1 2 1 1 3 39 1 4 76 3 4 1 1 1 1 41 1 2 80 1 2 1 1 2 1 42 1 4 81 3 4 1 1 1 1 44 1 2 85 3 4 1 1 1 1 1 45 1 4 87 1 1 1 1 47 1 2 91 1 1 2 1 48 1 4 92 1 4 1 1 2 49 3 4 94 3 4 1 1 2 1 1 52 98 3 4 1 1 1 4 53 1 2 101 1 4 1 1 1 2 54 1 4 102 3 4 1 1 1...

Page 10: ...lete separation from one floor space to an other or attic space as required by most codes When double wall pipe passes through a framed opening into an attic space firestop must be placed into an attic floor as shown in Figure 11 Figure 10 Firestop Spacer with Living Space Above Ceiling Figure 11 Firestop Spacer with Attic Space Above Ceiling IMPORTANT NOTICE When penetrating a ceiling into an att...

Page 11: ...aterial use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 14 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 14 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor ...

Page 12: ...nduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION Figure 18 Typical Residential Installations VENTING INSTALLATION Continued connection see Figure 20 page 13 Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal...

Page 13: ...WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING Do n...

Page 14: ... guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer Access Panel OPEN CLOSE Damper Handle Outside Air Kit Handle Keyway Slot Handle Retainer REPLACEMENT PARTS See Pages 15 to 17 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer P...

Page 15: ...White Brick 1 J4144 Right Refractory Textured White Herringbone 1 11 J4073 Rear Refractory Textured White Brick 1 J4147 Rear Refractory Textured White Herringbone 1 12 J4506 Bottom Rear Refractory White Brick 1 13 J4508 Bottom Front Refractory White Brick 1 PARTS WOOD BURNING FIREPLACE MODELS TUSCAN42P2 AND TUSCAN42P3 Rear Left Side Front Bottom Bottom Right Side MODEL NO CATALOG NO Tuscan42P2 F05...

Page 16: ...US com 127051 01D 16 PARTS WOOD BURNING FIREPLACE MODELS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 35 29 7 33 34 26 27 15 MODEL NO CATALOG NO Tuscan42P2 F0542 Tuscan42P3 F0543 ...

Page 17: ...Liner 1 11 See Page 15 Rear Refractory Brick Liner 1 12 See Page 15 Bottom Rear Refractory Brick Liner 1 13 See Page 15 Bottom Front Refractory Brick Liner 1 14 J3972 Firebox Support Leg 4 15 Damper Can Collar 1 16 J8013 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4471 Air Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 J45...

Page 18: ...F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F0886 30E 8HT 30 Degree Hi Temp Offset and Return F1908 30E 12DMO 8DMR 30 Elbow Set 12 to 8 Craftsman...

Page 19: ...on F0923 ETLO 8DM Square Top with Mesh and Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section STAINLESS STEEL HOOD Required when installing a vent free gas log in this fireplace F1053 HS42 42 Stainless Steel Hood w 4 Brow DRAIN PAN F1090 DP42 Drain Pan FIRESTOP THIMBLE F0911 ...

Page 20: ...HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Excess of 30 F0888 RT 8HT Hi Temp Round Top with Mesh Screen F0889 RTT 8HT Hi Temp Round Top with Mesh Screen and Slip Sec tion F0890 RLT 8HT Hi Temp Round Top with Louvere...

Page 21: ..._ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________...

Page 22: ..._ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________...

Page 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Page 24: ...uecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 127051 01 Rev D 10 2015 P127051 01 WARRANTY KEEP THIS WARRANTY 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Model Number Serial Number Date Installed Dealer s Name Dealer s Phone Number Keep receipt for warranty verification ...

Reviews: