Astria Tuscan42P2 Installation And Operation Instructions Manual Download Page 13

Astria.US.com

127051-01D

13

Figure 21 - Glass Doors

Cleaning Glass

Clean glass with any commercial glass cleaner or soap and water. 

Do not use any abrasive material to clean the glass. Do not clean 

glass with any cool water if glass is still hot from fire and smoke.

OPERATION AND MAINTENANCE

Doors Fully Closed

Doors Fully Opened

Fireplace Front

Fireplace Front

GLASS DOORS

Glass doors are optional with this fireplace. When fireplace is in 

operation, doors must be fully opened or fully closed position only 

or a fire hazard may be created (see Figure 21).

A fireplace equipped with glass doors operates much differently than 

a fireplace with an open front. A fireplace with glass doors has a 

limited amount of air for combustion. Excessive heat within fireplace 

can result if too large a fire is built or if combustion air gate is not 

completely open.
The following tips should be used to assure that both fireplace and 

glass door retain their beauty and function properly. Both the flue 

damper and glass doors must be fully opened before starting a 

fire. This will provide sufficient combustion air and maintain safe 

temperatures in firebox.

IMPORTANT: 

The glass must be allowed to warm slowly and evenly. 

Tempered glass will withstand a gradual temperature rise to 550° 

F, which is more than a normal fire will generate. Such materials as 

pitch/wax laden logs, very dry mill end lumber and large amounts 

of paper or cardboard boxes can create an excessively hot fire and 

should not be burned in this fireplace. Always keep fire back from 

doors and never allow flames to contact glass.

  WARNING: FIREPLACES EQUIPPED WITH DOORS 

SHOULD BE OPERATED ONLY WITH DOORS FULLY 

OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT 

PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT 

OF THE FIREPLACE OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE.

WARNING: Discontinue use of the appliance imme-

diately if doors are damaged and contact a qualified 

installer for repair. Only doors certified with the 

appliance shall be used.

 WARNING: Do not slam or strike doors. Damage 

can result in a hazardous condition.

Figure 20 - Gas Line Installation

Figure 19 - Gas Line Knockout

Side 

Firebrick 

Finished 

Side

Refractory 

Knockout 

Plug

Outside of Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas 

Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough 

Threaded End for 

Fitting Connection

If you install a decorative gas appliance (vented gas log), decorative 

gas appliance must comply with the Standard for Decorative Gas 

Appliance  for  Installation  in  Solid  Fuel  Burning  Fireplaces,  ANSI 

Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance 

with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/

CGA-B149.1 National Gas And Propane Installation Code (Canada).

 

WARNING: To avoid the risk of damaging fireplace 

materials and increasing the risk of spreading a fire, 

do not use fireplace to cook or warm food.

 WARNING: If the fireplace has been used for wood 

burning, firebox and chimney must be cleaned of soot, 

creosote and ashes be a qualified chimney cleaner. 

Creosote will ignite if heavily heated.

 WARNING: When using a decorative vented gas 

log, damper must be removed or permanently locked 

in fully open position and glass doors must be in fully 

open position.

OPTIONAL GAS LINE INSTALLATION 

Continued

Summary of Contents for Tuscan42P2

Page 1: ...og heater see Accessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de déterminer la nécessité d obtenir un ...

Page 2: ...dification of the fireplace components doors air inlet system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all...

Page 3: ...to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service te...

Page 4: ...USTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE PERPENDICULAR NOT LESS THAN 12 TO SIDEWALL 41 48 42 8 39 12 48 36 24 8 1 8 10 5 8 12 5 8 10 5 8 6 3 4 14 1 4 2...

Page 5: ...mum Maximum Chimney Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections required for outdoor installation Figure 1 Framing Dimensions Figure 2 Corner Installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 1 and 2 Note Whe...

Page 6: ...pan with provision for drainage be installed under the fireplace within the fireplace enclosure see Accessories page 19 HEARTH EXTENSION A hearth extension projecting a minimum of 20 in front of and a minimum of 12 beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace Fab ricate a hearth extension using a material which meets the followin...

Page 7: ... 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in lineal gain chart see Figure 6 Lineal gain is actual measurable length of a part after two or more parts are connected Figure 6 Lineal Gain Hemmed End 8 Stainless Inner Pipe 1...

Page 8: ... page 9 The height of a vertical chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSET 30E 12DMO 8DMR To clear overhead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be used...

Page 9: ... 24 1 2 50 3 4 1 1 2 27 1 2 56 1 1 1 1 30 1 4 61 1 1 2 31 62 1 2 1 1 1 32 1 2 65 1 1 2 1 35 1 2 70 1 4 1 1 1 2 36 1 4 71 1 2 1 1 1 1 37 72 3 4 1 1 1 38 1 2 75 1 2 1 1 3 39 1 4 76 3 4 1 1 1 1 41 1 2 80 1 2 1 1 2 1 42 1 4 81 3 4 1 1 1 1 44 1 2 85 3 4 1 1 1 1 1 45 1 4 87 1 1 1 1 47 1 2 91 1 1 2 1 48 1 4 92 1 4 1 1 2 49 3 4 94 3 4 1 1 2 1 1 52 98 3 4 1 1 1 4 53 1 2 101 1 4 1 1 1 2 54 1 4 102 3 4 1 1 1...

Page 10: ...lete separation from one floor space to an other or attic space as required by most codes When double wall pipe passes through a framed opening into an attic space firestop must be placed into an attic floor as shown in Figure 11 Figure 10 Firestop Spacer with Living Space Above Ceiling Figure 11 Firestop Spacer with Attic Space Above Ceiling IMPORTANT NOTICE When penetrating a ceiling into an att...

Page 11: ...aterial use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 14 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 14 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor ...

Page 12: ...nduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION Figure 18 Typical Residential Installations VENTING INSTALLATION Continued connection see Figure 20 page 13 Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal...

Page 13: ...WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING Do n...

Page 14: ... guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer Access Panel OPEN CLOSE Damper Handle Outside Air Kit Handle Keyway Slot Handle Retainer REPLACEMENT PARTS See Pages 15 to 17 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer P...

Page 15: ...White Brick 1 J4144 Right Refractory Textured White Herringbone 1 11 J4073 Rear Refractory Textured White Brick 1 J4147 Rear Refractory Textured White Herringbone 1 12 J4506 Bottom Rear Refractory White Brick 1 13 J4508 Bottom Front Refractory White Brick 1 PARTS WOOD BURNING FIREPLACE MODELS TUSCAN42P2 AND TUSCAN42P3 Rear Left Side Front Bottom Bottom Right Side MODEL NO CATALOG NO Tuscan42P2 F05...

Page 16: ...US com 127051 01D 16 PARTS WOOD BURNING FIREPLACE MODELS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 35 29 7 33 34 26 27 15 MODEL NO CATALOG NO Tuscan42P2 F0542 Tuscan42P3 F0543 ...

Page 17: ...Liner 1 11 See Page 15 Rear Refractory Brick Liner 1 12 See Page 15 Bottom Rear Refractory Brick Liner 1 13 See Page 15 Bottom Front Refractory Brick Liner 1 14 J3972 Firebox Support Leg 4 15 Damper Can Collar 1 16 J8013 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4471 Air Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 J45...

Page 18: ...F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F0886 30E 8HT 30 Degree Hi Temp Offset and Return F1908 30E 12DMO 8DMR 30 Elbow Set 12 to 8 Craftsman...

Page 19: ...on F0923 ETLO 8DM Square Top with Mesh and Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section STAINLESS STEEL HOOD Required when installing a vent free gas log in this fireplace F1053 HS42 42 Stainless Steel Hood w 4 Brow DRAIN PAN F1090 DP42 Drain Pan FIRESTOP THIMBLE F0911 ...

Page 20: ...HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Excess of 30 F0888 RT 8HT Hi Temp Round Top with Mesh Screen F0889 RTT 8HT Hi Temp Round Top with Mesh Screen and Slip Sec tion F0890 RLT 8HT Hi Temp Round Top with Louvere...

Page 21: ..._ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________...

Page 22: ..._ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________...

Page 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Page 24: ...uecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 127051 01 Rev D 10 2015 P127051 01 WARRANTY KEEP THIS WARRANTY 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Model Number Serial Number Date Installed Dealer s Name Dealer s Phone Number Keep receipt for warranty verification ...