INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame. Alterations
may have occurred during shipping and handling. The pilot is located
on right hand side of burner.
The flame must envelope 1/4" of top of the igniter/sensor and ground-
ing stem.
If your pilot assembly does not meet these requirements:
• Turn the adjustment screw marked PILOT clockwise to decrease or
counterclockwise to increase the flame to proper size
(see
Figure
37, Page 24
).
Do not remove the adjustment screw.
• see Troubleshooting,
Page 28.
BURNER FLAME PATTERN
Burner flames will be steady, not lifting or floating. Flame patterns will
be different from unit to unit and will vary depending on installation
type and weather conditions.
If the vent configuration is installed incorrectly, flames will lift or
"ghost". This can be dangerous. Inspect flames after installation to
ensure proper installation and performance.
Figure 40
shows a typical flame pattern.
If burner flame pattern differs from that described:
• turn fireplace off
(see To Turn Off Gas to Appliance,
Page 24
)
• see Troubleshooting,
Page 28
Sensing Rod
Pilot Burner
Igniter
Pilot
Burner
Igniter/
Sensor
Sensing
Rod
Figure 38 - Pilot
Figure 40 - Typical Flame Pattern
Figure 39 - Correct Pilot Flame Pattern
CAUTION: Hot while in operation. Do not touch.
Severe Burns may result. Keep children, clothing,
furniture, gasoline and other liquids having flammable
vapors away.
ATTENTION : L'appareil est chaud lorsqu'il fonc-
tionne. Ne pas toucher l'appareil. Risque de brûlures
graves. Surveiller les enfants. Garder les vêtements,
les meubles, l'essence ou autres liquides produisant
des vapeur inflammables loin de l'appareil.