Astria.us.com
126733-01H
21
Volcanic stone
Figure 30 - Installing Volcanic stone
Figure 31 - Installing Ember Flakes
Figure 32 - Installing Scrap Log Pieces
Figure 33 - Connecting/Disconnecting Gas Line to Control Valve
Figure 34 - Removing/Installing Burner Base
Ember Flakes
Scrap Log Pieces
FIREPLACE INSTALLATION
Continued
REMOVING LOG SET/BURNER MODULE
Connecting and Disconnecting Gas Line
WARNING: A qualified service person must con-
nect and disconnect fireplace with gas supply. Follow
all local codes.
1. Using a 5/16" hex socket wrench or nut-driver, connect or discon-
nect flexible gas line and control valve
(see
Figure 33
).
2. After connecting gas line to control valve, always test for leaks.
Equipment
Shutoff
Valve
Control Valve
Flexible Gas
Line, Do NOT
Kink
To Gas Supply
(Natural)
To External
Regulator
(Propane/LP)
WARNING: Never use an open flame to check for a
leak. Apply noncorrosive leak detection fluid to joints.
Bubbles forming show a leak. Correct leaks at once.
CAUTION: The gas supply shall be shut off prior
to disconnecting the electrical power, if any, before
proceeding with this installation.
CAUTION: Use gloves when removing the log set/
burner module from your firebox. Some metal edges
may be sharp. Use caution with log sets as logs are
fragile.
1. Remove glass door
(see
Page 19
).
2. Remove grate and all floor media (see Removing Log Set/Burner
Module).
3. Carefully lift and remove 3 hearth refractories from fireplace.
4. Remove 3 spacers from firebox bottom
(see
Figure 34
)
.
5.
For 36" models only:
Remove 3 loose logs from log set
(see
Figures 29, 29a, and 29b, Page 20
).
6. Remove 9 screws from front and sides of firebox burner base. Lift
entire base from unit by pulling forward to disengage from rear
flange and then lifting up
(see
Figure 34
).
7. If needed, replace burner gasket before reinstalling log set/burner
module
(see replacement parts list on
Page 31
).
Log Assembly
Firebox Bottom
Burner Base
Screws
Spacers
f i r e - p a r t s . c o m